![background image](http://html1.mh-extra.com/html/campbell/raws-p/raws-p_instruction-manual_3815639022.webp)
RAWS-P Remote Automated Weather Station
5.4.2 Wiring, GOES Transmitter (part #TX312)
The GOES transmitter (part #TX312)
is mounted inside the RAWS
environmental enclosure and the transmitter connections are described below;
GOES Transmitter TX312 Connection inside the RAWS environmental
enclosure
GOES TX312 “CSI/O” Port
--to-- CR1000 PC Board “CSI/O” Port using
a *SC12 Cable
GOES TX312 “GPS Port”
--to-- GPS Antenna Cable
GOES TX312 “RF Out”
--to-- GOES Antenna Cable
GOES TX312 “Power Port”
--to-- Battery Cable Junction Connector
*Note: The SC12 Cable ships with the RAWS Quick Deployment Weather
Station.
5.4.3 Troubleshooting, GOES Transmitter (part #TX312)
If a problem with the GOES transmitter (part #TX312) is suspected, the TX312
may be checked by measuring the +12 V and Ground terminal on the CR1000
PC-board wiring panel. Acceptable readings are +11 VDC to +14 VDC.
Check the SC12 cable connection between the CR1000 wiring panel and the
TX312. Press the TX312 diagnostic button to query the state of the
transmitter. If problems persist, try a substitute. Obtain a Return Material
Authorization (RMA) number before returning this equipment to Campbell
Scientific for repair.
Consult the TX312 manual for more information.
NOTE
5.5 Voice Radio Interface
5.5.1 General Description, Voice Radio Interface (part #VSP3)
The DACOM Voice Radio Interface (part #VSP3) shown in Figure 5.5-1 is
mounted inside the RAWS environmental enclosure. The VSP3 converts data
into voice messages that can be transmitted via UHF or VHF transceiver. The
VSP3 Vosponder uses phonetic native text string to speech conversion, which
provides for an unlimited vocabulary. The Vosponder communicates with a
datalogger using the SDI-12 protocol. The VSP3 Vosponder can be integrated
into an existing UHF/VHF radio network. A minimum of two radios with
matching frequencies is required. The VSP3 ships preprogrammed with a
voice image file for the fire weather market.
A minimum of two radios with matching frequencies is required
to transmit voice messages. To activate the voice file, hold down
the radio microphone button and press 9 on the radio keypad.
Radios can be purchased from Campbell Scientific.
NOTE