Appendix A. AceManager Setup without Template File
•
S23 — Configure Serial Port — The baud rate needs to be configured to
match a valid datalogger baud rate. For a CR10X: 9600,8N1 and for a
CR1000: 115200,8N1.
•
\Q — Serial Port Flow Control — This should be set to None.
•
V — AT Verbose Mode — Set this to Verbose for CR800, CR1000,
CR3000; Numeric for CR10(X), CR510, CR23X.
•
&D — DTR Mode — Set to Ignore DTR
•
S211 — DTR Mode – Set to Ignore DTR
•
S0 — TCP Auto Answer — Set to On
•
TCPT — TCP Idle Timeout — Set to a reasonable value like 2 min.