Specifications

Enclosure: Molded medium density linear polyethylene, three 
piece construction and stainless-steel fittings
Cooling System: Insulated container wall cavity space for ice
Height: 80.9 cm (31.875 in.)
Height with extended base: 96.2 cm (37.875 in.)
Body Case Diameter: 42.8 cm (16.85 in.)
Sampler Weight, no battery: 11.8 kg (26 lb)
Battery Weight: 6.8 kg (15 lb)

Vacuum System

Pinch Valve: Fixed – normally open
Purge Cycle: Adjustable from 1 to 99 s
Suction Cycle: Variable (adjusts automatically to double the 
input value of the purge time setting or until liquid contacts 
level electrode in metering chamber
Metering Chamber Cover: Nylon

Volume Control Tube: 316 stainless steel

Metering Chamber Level Electrode: 316 stainless steel
Intake Hose: ordered as a common accessory. Campbell Scientific 
offers PVC hose with 25 ft and user-specified lengths. Intake end 
can have a lead sinker or stainless-steel strainer. Sampler end can 
have a clamp or quick connect termination.
Discharge Hose Material:  Latex

Controller

LCD: 2 x 16 character backlit LCD

Touchpad: 16 key with multi-level menu

Start Delay: Disabled; Time/Day; Pulse Count; 4 to 20 mA  
(0 to 100 pulses/min.); External Contact; Level Control
Sample Initiation: Disabled; Time/Day; Pulse Count; 4 to 20 mA 
(0 to 100 pulses/min.); External Contact
Program Type: Composite; Multi-Composite; Consecutive; Daily  
Cycle; Timed Step
Clock: Real-time clock and operating system
Direct Function Keys: Manual sample; Manual purge; Manual 
bottle advance; Restart
Switches: Controller on/off (SPST toggle)
Available Displays: Real-time clock; process timing; process 
totals; pulse counting; event response; multilevel descriptions; 
flashing prompts; diagnostics
Automatic Displays: Container Full; Fault; Power Interrupt (pro-
gram resumed); Alternating Time Stamp; Cycle(s) abandoned
Backup Power Source: Internal lithium battery to maintain 
program settings and information in case of power failure

Power Requirements

DC Output: 13.6 Vdc, 10 A
AC Input: 88 to 264 Vac, 50/60 Hz, 2.5 A (nominal), 3 A (maximum)
Backup Battery: 12 Vdc
Quiescent Current Drain: 61 mA

Vacuum Pump

The PVS4100C and PVS4100D samplers use an external vacuum 
pump to draw water through intake tubing, instead of the tra-
ditional peristaltic pump that induce flow by squeezing flexible 
tubing.  Because the vacuum method disturbs the water samples 
less, they better represent the original water solution, especially 
if the solution has high concentrations of suspended solids.  To 
prevent cross contamination, the samplers use air pressure (up 
to 28 psi) to purge the tubing of excess water.  See our vacuum 
pump water samplers in action at:

www.youtube.com/watch?v=wi4dxFTw-ks

Controller/Interfacing with a Datalogger

The PVS4100C and PVS4100D include a programmable controller 
with 16-key intuitive touch pad. The controller can accept a pulse 
input (e.g., rain gage), a 4 to 20 mA signal (e.g., flow meter), or 
initiate a sample on a timed basis.  See a demonstration of the 
programmable controller at: 

www.youtube.com/watch?v=yRr80Lm-5Hs

The sampler can also be interfaced with our dataloggers.  Our 
dataloggers can measure nearly any turbidity, water level, or 
hydrometeorologic sensor, as well as control the sampler based 
on time, event, or measured conditions.

Technical Details

Horizontal Velocity

System Size

Distance

7.6 m (25 ft)

15.2 m (50 ft)

22.9 m (75 ft)

30.5 m (100 ft)

53.3 m (175 ft)

61 m (200 ft)

76.2 m (250 ft)

3/8 in. system

2.2 m s

-1

  

(7.1 ft s

-1

)

1.9 m s

-1

  

(6.2 ft s

-1

)

1.7 m s

-1

  

(5.6 ft s

-1

)

1.5 m s

-1

  

(5 ft s

-1

)

1.2 m s

-1

  

(4 ft s

-1

)

1.1 m s

-1

  

(3.7 ft s

-1

)

0.8 m s

-1

  

(2.6 ft s

-1

)

5/8 in. system

(PVS4100C only)

1.5 m s

-1

  

(5 ft s

-1

)

1.4 m s

-1

  

(4.7 ft s

-1

)

1.3 m s

-1

  

(4.3 ft s

-1

)

1.28 m s

-1

  

(4.2 ft s

-1

)

1.1 m s

-1

  

(3.7 ft s

-1

)

1 m s

-1

  

(3.3 ft s

-1

)

0.7 m s

-1

  

(2.4 ft s

-1

)

Reviews: