Section 3. Report: SPLIT
PC208W, Version 3.3, Instruction Manual
3-31
This .PAR file produces a wind chill summary of the Mt. Logan Peak data set.
The formula for calculating wind chill is given as follows:
Te
= 33-(h/22.066)
where
Te
= Wind Chill equivalent temperature, degrees C
h
= ((100V)
0.5
+ 10.45-V)(33-T)
where
h
= Kcal m
-2
hr
-1
wind chill index
v
= wind speed in meters/second
T
= temperature in degrees C
Note that at wind speeds between 0 to 4 mph (0 to 1.8 m/s), the wind chill
should be ignored because this formula results in wind chill temperatures that
are greater than the ambient temperature. The National Weather Service
includes wind chill in reports only when temperatures drop below 35
°
F
(1.7
°
C).
1
The formula is for example purposes and is not endorsed by
Campbell Scientific as a standard.
When this .PAR file is executed, the following output is displayed on the
screen.
Summary of Contents for PC208W
Page 2: ...This is a blank page...
Page 4: ......
Page 58: ...Section 2 Program EDLOG 2 18 PC208W Version 3 3 Instruction Manual This is a blank page...
Page 98: ...Section 3 Report SPLIT 3 40 PC208W Version 3 3 Instruction Manual This is a blank page...
Page 126: ...Section 6 Program Conversion 6 4 PC208W Version 3 3 Instruction Manual This is a blank page...
Page 156: ...This is a blank page...