stay ON solid (indicating it has achieved its specific operational
status).
x
CONFIG (Button) - Holding this button depressed while powering-up
the IPn3G will boot the unit into FLASH FILE SYSTEM
RECOVERY mode. The default IP address for system recovery (only
- not for normal access to the unit) is static: 192.168.1.39.
x
If the unit has been powered-up for some time (>1 minute), depressing
the CFG Button for 8 seconds will result in FACTORY DEFAULTS
being restored, including a static IP address of 192.168.0.1. This IP
address is useable in a Web Browser for accessing the Web User
Interface.
6.2.2 Modem Back
The back of the modem includes the Antenna SMA(F) connector, power
connection, Data (RS-232) port, and Ethernet port
Figure 6—2 Rear view of the IPn3Gb Cellular Modem
x
The Antenna required for the application is connected to the Antenna
connector. The GPS and RX DIV are not used.
x
The Green connector plug included with the modem is used to make
the power connection. Connections and use of the RS485/422 are not
referenced in this manual.
x
The DATA port is used to connect to a datalogger’s RS-232 or CS I/O
port.
x
The Ethernet port can be used to configure the modem. See
Section
6.3.3.2
for details. The Ethernet port can also be used to communicate
with a datalogger and compatible interface using a compatible
network link interface (see Section 5.5.3).
23