3. On the PPP tab, set Config/Port Used to the CS I/O SDC address selected in the module or
RS-232 depending on how you will be connected to the data logger.
4. Verify the Modem Dial String setting is blank.
5. (Optional) If using CS I/O communication, the throughput can be enhanced by changing
the SDC Baud Rate from 115200 to 460800. On the Advanced tab, set the SDC Baud Rate to
460800. Note that if there are other devices on the CS I/O port, they all must be able to
support this higher baud rate.
6.4.2.3 Set up hardware
1. Connect the Cellular antenna.
2. Connect your data logger to the CELL200-series module RS-232 or CS I/O port. See
3. If not connecting through CS I/O, provide power to the CELL200 series.
6.4.2.4 Set up LoggerNet
The LoggerNet Network Map is configured from the LoggerNet Setup screen.
NOTE:
Setup has two options, EZ (simplified) and Standard. Click on the View menu at the top of
the Setup screen, and select Standard view.
From the LoggerNet toolbar, click Main > Setup and configure the Network Map as described in
the following steps:
1. Select Add Root > IPPort.
2. Select PakBusPort and pbRouter for PakBus data loggers such as the CR1000X or CR300.
3. Add a data logger to the pbRouter.
CELL200-Series 4G LTE Cellular Module