![Campbell CCFC Instruction Manual Download Page 85](http://html1.mh-extra.com/html/campbell/ccfc/ccfc_instruction-manual_3745995085.webp)
CCFC Field Camera
75
Figure 13-2 L28840 DB9 FEMALE to Terminal Block Adapter
Table 13-1 CCFC Connections to RS-232 Port
Wire Colour
Function
Connection Required
Red
Power
9 to 30 Vdc
Black
Shield
Pin 5 and Power Ground
White
Rx (input)
Pin 3
Green
Tx (output)
Pin 2
The required RS-232 connections to a datalogger are shown in Table 13-2.
Table 13-2 Datalogger Connections to RS-232 Port
Wire Colour
Function
Connection Required
Red
Power
12 V
Black
Shield
Datalogger G (Ground)
White
Rx (input)
Control Port Tx
Green
Tx (output)
Control Port Rx
Blue
Ext Trigger
Control Port (optional)
Yellow
Switched PWR Do no connect