CC5MPX & CC5MPX-Z Digital Network Camera
82
The following SerialOpen instruction configures COM port 2.
•
BAUD rate - 115200
•
PakBus Port – 4
•
Transmit delay - 0,
•
Buffer size - 1000.
SerialOpen (Com2,115200,4,0,1000)
17. Remote Image Retrieval
Once the camera has transferred an image or video to a datalogger, existing
Loggernet communications can be used to retrieve images and video remotely
from the datalogger memory.
There are also permanent links available in the CC5MPX webserver to
download the most recently captured images or video files that have been
saved to the SD card. Refer to Section 5.4.1 for details.
17.1 Loggernet File Retrieval
LoggerNet (Version 4.0 or newer) includes the File Retrieval setup that
facilitates the image and video file retrieval from PakBus dataloggers (CR800
series, CR1000, and CR3000). The File Retrieval tab is located in the Setup
Screen as part of the datalogger configuration. Once configured, the File
Retrieval software is used to retrieve images and video from a datalogger.
Figure 17-1 File Retrieval Setup Screen
Select the required Retrieval Mode for the application. The use of the “Follow
Scheduled Data Collection” option will use the scheduled configured in the
Schedule tab. If the “New Schedule” option is selected you will need to
configure the Base Date and Time, and the Retrieval Interval parameters.
File Retrieval
Setup Screen