CC5MPX & CC5MPX-Z Digital Network Camera
90
remove the CC5MPX from any power supply and disconnect any attached
cabling.
To remove the backplate first start by removing the 6 Philips screws located
along the perimeter of the cameras backplate (see Figure 20-1 Backplate
View). Note that there are two washers that are included with the protective
cover chains of the button cap and the RJ45 cap.
After the screws are removed, gently pull the backplate out. The backplate
will still be attached to the camera with the wires. Do not remove the wires.
Pivot the backplate to the left side of the camera. You will now have access to
the inside of the camera.
When replacing the backplate ensure that the O-ring is still seated properly on
the backplate (see Figure 19-1 Backplate O-ring). This is very important as the
O-ring is required to properly seal the camera.
The backplate can only be seated in the orientation that aligns the flat surfaces
of the backplate and the bottom of the camera body. This will also help align
the screw holes. The six screws can now be threaded and hand tightened. Be
sure the two plastic washers are located between the tether chains and the
backplate.
Figure 20-1 Backplate View