![background image](http://html1.mh-extra.com/html/campbell-hausfeld/tl0539/tl0539_operating-instructions-manual_3850059011.webp)
9
USER - MAINTENANCE INSTRUCTIONS
Release all pressure before attempting to install,
service, relocate or perform any maintenance on the
air system. Personal injury and/or property damage could occur.
Hydraulic Cylinder
Occasionally, the hydraulic
cylinder will need hydraulic fluid.
To fill the hydraulic cylinder,
follow the procedure outlined
below (See Figure 5).
1.
Release all system pressure
and disconnect the rivet
gun.
2.
Hold gun upside down.
3.
Remove bottom plate and
air piston.
4.
Look into small bore at
bottom of chamber to
check hydraulic oil level.
5.
Hydraulic oil level should
be about 1/2” from top
of small piston bore (total
capacity: 60 - 70 cc).
Storage
The rivet gun must be lubricated before storing. Follow the lubrication
instructions with the exception of step 4. Trigger the gun only once or twice
because more oil needs to remain in the gun for storage.
Technical Service
For information regarding the operation or repair of this product, please visit
www.campbellhausfeld.com
Figure 5
Piston
Exhaust
Port
Bottom
Plate
Piston Bore
Hydraulic Fluid
Fill Level
Safety Cap
Summary of Contents for TL0539