Troubleshooting Chart

 Symptom 

Possible Cause(s) 

Corrective Action

Tool runs slowly or will not 
operate

Moisture blowing out of tool

Excessive vibration

1.  Grit or gum in tool

2.  No oil in tool

3.  Low air pressure

4.  Air hose leaks

5. Pressure 

drops

6.  Regulator adjusted  
 wrong

1.  Water in tank

2.  Water in the air  
 lines/hoses

1. Damaged 

wheel 

2.  Arbor shaft bent

1. 

Flush the tool with Campbell Hausfeld air tool oil, gum  

 

solvent, or an equal mixture of SAE 10 motor oil and    

 

kerosene. If Campbell Hausfeld oil is not used, lubricate  

 

the tool after cleaning.

2. 

Lubricate the tool according to lubrication instructions in  

 Pre-Operation 

section.

3. 

Adjust the compressor regulator to tool maximum while  

 

the tool is running free.

4. 

Tighten and seal hose fittings if leaks are found.

5. 

Be sure hose is properly sized. Long hoses or tools using  

 

large volumes of air may require a hose with an I.D. of  

 

1/2 inch or larger depending on total hose length.

6. 

Adjust regulator with slotted screwdriver to maximum  

 speed.

1. 

Drain tank (See air compressor manual). Oil tool and run  

 

until no water is evident. Oil tool again and run 1-2    

 seconds.

2a.  Install a water separator/filter (PA2121). 

NOTE:

 Separators  

 

work properly only when air steam is cool Locate  

 

 

separator/filter as far as possible from compressor.

2b.  Install an air dryer.

2c. 

Anytime water enters the tool, the tool should be oiled  

 immediately.

1. 

Replace cutting wheel (MP2879).

2. Replace 

tool.

3

Operating Instructions

www.campbellhausfeld.com

Summary of Contents for TL0535

Page 1: ...the equipment 2 Only persons well acquainted with these rules of safe operation should be allowed to use the air tool Do not exceed the maximum oper ating pressure of the air tool 90 psi This can redu...

Page 2: ...orten the life of the tool and will void the warranty This air tool requires lubrication before initial use and before and after each additional use 1 Disconnect tool from air supply 2 Turn cutting to...

Page 3: ...3 Adjust the compressor regulator to tool maximum while the tool is running free 4 Tighten and seal hose fittings if leaks are found 5 Be sure hose is properly sized Long hoses or tools using large vo...

Page 4: ...to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices are removed or altered this warranty is void D Normal adj...

Page 5: ...utions de s curit suivantes doivent tre prises en permanence en m me temps que toute autre r gle de s curit en vigeur 1 Lire attentivement tous les manuels y compris celui de ce produit Bien se famili...

Page 6: ...e l huile et des bords tranchants Remplacer tout tuyau endommag peu robuste ou us Pr Fonctionnement GRAISSAGE Il est n cessaire de graisser les outils pneumatiques au cours de leur dur e Le graissage...

Page 7: ...de graissage dans la section Pr Fonctionnement 3 R gler le r gulateur du compresseur la position maximum lorsque l outil fonctionne librement 4 Serrer et assurer l tanch it des raccords du tuyau en ca...

Page 8: ...les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de s ret Si ces appareils de s ret sont enlev s ou modifi s la garantie sera annul e D R gl...

Page 9: ...l equipo 2 La herramienta neum tica s lo debe ser usada por personas que est n bien familiarizadas con las reglas de seguridad de manejo Nunca exceda la capacidad m xima de presi n de la herramienta n...

Page 10: ...en causar da os a las manos y los brazos Si siente incomodidad p rida de sensaci n hormigueo o dolor suspenda el uso de cualquier herramienta y consulte a un m dico Ensamblaje INSTALACI N DEL SISTEMA...

Page 11: ...mienta mientras sta funciona en vac o 4 Apriete y selle las conexi nes de la manguera si encuentra alguna fuga 5 Aseg rese de que la manguera es de tama o adecuado Las mangueras largas o las herramien...

Page 12: ...aci n de los instrumentos de seguridad Si dichos instrumentos de seguridad son desconectados la garant a quedar a cancelada D Los ajustes normales explicados en el los manual es suministrado s con el...