PA210100AV
www.campbellhausfeld.com
3
Installation
Disconnect power and release
all pressure from the system
before attempting to install, service,
relocate or perform any maintenance.
1. Locate the air flow direction arrow
(See Figure 2, detail). This arrow
shows the direction of the air flow.
2. Install the gauge (if applicable). Use
PTFE tape on threads.
3. Remove plug(s) from plastic bag. The
plug(s) have pre-applied sealant. No
additional sealant is required. Install
plug(s) into the open 1/8 inch NPT
hole(s).
4. Securely mount the regulator in any
position as close as possible to air
tool connection.
5. Verify the arrow points in the direction
of the air flow. (See Figure 2.)
6. Install the unit with the same pipe
size as the piping in use. Avoid using
unnecessary fittings, couplings, etc.,
that restrict airflow.
7. Connect the air supply to the 3/8 inch
NPT inlet port.
Operation
Ensure the regulator adjusting
knob is unlocked when
adjusting pressure. The regulator will
be damaged if the knob is turned in the
locked position.
1. Unlock the regulator adjusting knob
by pulling knob away from the
regulator.
2. Turn the regulator adjusting knob
counterclockwise until no load is on
the regulating spring.
3. Turn on the air pressure supply and
turn the adjusting knob clockwise
until the desired outlet pressure is
reached. Push the regulator adjusting
knob toward the regulator to lock in
desired pressure.
Maintenance
Release all pressure before
attempting to install, service,
relocate or perform any
maintenance on the air system. Personal
injury and/or property damage could
occur.
technIcal seRvIce
For information regarding the operation or
repair of this product, please call 1-855-
504-5678.
Figure 2 - detail showing location of flow
direction arrow
Flow direction arrow