background image

Store electrodes in a clean, dry
location with low humidity to
preserve the flux coating.

The receptacle used for the welder
must be properly grounded and the 
welder must be the only load on the
power supply circuit. Refer to the
Circuit Amps chart on page 1 for
correct circuit capacity.

The use of an extension cord is not
recommended for arc welding
machines. Extension cord use will
significantly degrade the
performance of the welder.

A s s e m b l y

HANDSHIELD (OPTIONAL)

1 . Cut detachable handle away from

shield. Trim the excess plastic to
remove sharp edges.

2 . Insert filter lens.

CALIFORNIA PROPOSITION 65

This product, when used for welding,
produces fumes or gases which contain
chemicals known to the State of
California to cause birth defects (or
other reproductive harm) and, in some
cases, cancer (California Health & Safety
Code Section 25249.5 et seq.).

The power cord and other cables on
this product contain chemicals,
including lead, known to the State of
California to cause [cancer and] birth
defects or other reproductive harm.
Wash hands after handling.

Do not breathe fumes that
are produced by the arc
welding operation. These
fumes are dangerous. If the
welding area cannot be adequately
ventilated, be sure to use an air-
supplied respirator.

Keep the head and face out of the
welding fumes.

Do not perform electric arc welding
operations on metals that are
galvanized or cadmium plated, or
contain zinc, mercury, or beryllium
without completing the following
p r e c a u t i o n s :

a . Remove the coating from the

base metal.

b . Make sure that the welding area

is well ventilated.

c . Use an air-supplied respirator.

Extremely toxic fumes are created
when these metals are heated.

The electromagnetic field
that is generated during arc
welding may interfere with
the operation of various
electrical and electronic devices such as
cardiac pacemakers. Persons using such
devices should consult with their
physician prior to performing any
electric arc welding operations.

 

Route the electrode and work
cables together and secure with
tape when possible.

 

Never wrap arc welder cables
around the body.

Always position the electrode and
work leads so that they are on  t h e
same side of the body.

3

Exposure to electromagnetic fields
during welding may have other
health effects which are not known.

Always be sure

that the welding area

is secure and free of hazards (sparks, flames,
glowing metal or slag) prior to leaving. Be
sure that equipment is turned off and
electrode is removed. Be sure that cables
are loosely coiled and out of the way. Be
sure that all metal and slag has cooled.

ADDITIONAL SAFETY STANDARDS

ANSI Standard Z49.1 

from American

Welding Society, 550 N.W. LeJune Rd.
Miami, FL 33126

Safety and Health Standards

OSHA 29 CFR 1910, from
Superintendent of Documents, U.S.
Government Printing Office,
Washington, D.C. 20402

National Electrical Code

NFPA Standard 70, from National Fire
Protection Association, 1 Batterymarch
Park, Quincy, MA 02169

Safe Handling of Compressed Gases
in Cylinders

CGA Pamphlet P-1, from Compressed
Gas Association, 1235 Jefferson Davis
Highway, Suite 501, Arlington, VA
2 2 2 0 2

Code for Safety in Welding and
C u t t i n g

CSA Standard W117.2, from Canadian
Standards Association, Standards Sales,
178 Rexdale Boulevard, Rexdale,
Ontario, Canada M9W 1R3

Cutting And Welding Processes

NFPA Standard 51B, from National Fire
Protection Association, 1 Batterymarch
Park, Quincy, MA 02169

Safe Practices For Occupational And
Educational Eye And Face
P r o t e c t i o n

ANSI Standard Z87.1, from American
National Standards Institute, 1430
Broadway, New York, NY 10018

Refer to the Material Safety Data
Sheets and the manufacturers
instructions for metals, electrodes,
coatings and cleaners.

Installation

L o c a t i o n

Selecting the proper location can
significantly increase performance,
reliability and life of the arc welder. 

For best results locate the welder in
an environment that is clean and
dry. Dust and dirt in the welder
retain moisture and increase wear
of moving parts.

w w w . c h p o w e r . c o m

Figure 2 

Figure 3

Figure 4

General Safety

( C o n t i n u e d )

M o d e l WS0970 and WS0990

Summary of Contents for IN972101AV

Page 1: ...circuit breaker or fuse rating Do not run other appliances lights or tools on this circuit while operating this equipment Extension cords are not recommended Blown fuses or tripped circuit breakers c...

Page 2: ...etal can cause injury As welds cool slag can be thrown off Take all precautions described in this manual to reduce the possibility of injury from flying sparks and hot metal Wear ANSI approved face sh...

Page 3: ...electric arc welding operations Route the electrode and work cables together and secure with tape when possible Never wrap arc welder cables around the body Always position the electrode and work lea...

Page 4: ...ate receptacle 115v 15 amp Low 115v 20 amp High 3 Verify that the surfaces of metals to be joined are free from dirt rust paint oil scale or other contaminants These contaminants make welding difficul...

Page 5: ...the electrode stick to the work piece break it loose by quickly twisting or bending at the holder while pulling upward If the electrode does not break loose disengage the electrode by releasing it fro...

Page 6: ...e welding rod Control travel speed to obtain a consistent bead width SLAG REMOVAL Wear ANSI approved safety glasses ANSI Standard Z87 1 and protective clothing when removing slag Hot flying debris can...

Page 7: ...is first followed by filler passes and the cover pass See Figure 10 If the pieces are thick it may be necessary to bevel the edges that are joined at a 60 angle Remember to remove the slag between eac...

Page 8: ...Run welder on dedicated 115V circuit Welder does not hum when turned on Welder hums but does not weld Welder gives trickle shocks Welder overheats blows fuses trips circuit breaker Arc difficult to st...

Page 9: ...imitations on how long an implied warranty lasts so above limitations may not apply to you C This warranty does not apply to any accessory items included with the product which are subject to wear fro...

Page 10: ...t shown DK687500AV 1 Safety decal 1 of 2 for WS0990 not shown DK687502AV 1 Safety decal 2 of 2 for WS0990 not shown DK687503AV 1 4 Chipping hammer brush not shown WC803400AV 5 Hand shield not shown WC...

Page 11: ...11 Model WS0970 and WS0990 www chpower com Notes...

Page 12: ...the work piece Filler metal may or may not be used Lap Joint a joint between two overlapping members in parallel planes Open Circuit Voltage OCV the voltage between the electrode and the work clamp of...

Page 13: ...es recommandations peut avoir comme r sultat fusibles saut s et disjoncteurs d clench s G n ralit s sur la S curit Manque de suivre cet avertissement de danger causera la perte de vie ou blessures gra...

Page 14: ...st pas en usage et enlever l lectrode du porte lectrode Ne jamais permettre que votre corps touche l lectrode et le contact la terre ni l objet de travail mis la terre simultan ment Les conditions et...

Page 15: ...endroit de soudage n est pas bien ventil Garder la t te et le visage hors des vapeurs de soudage Ne pas ex cuter le soudage lectrique l arc sur les m taux qui sont galvanis s ou plaqu s en cadmium ou...

Page 16: ...arc La perte de tension dans le cordon prolongateur peut r duire le rendement du soudeur Montage MASQUE MAIN OPTIONNELS 1 loigner la poign e amovible du masque Couper l exc s de plastique pour enlever...

Page 17: ...bles de soudage et r parer ou remplacer imm diatement les c bles qui ont de l isolation endommag Quand le courant amp rage passe du circuit l lectrode un arc est produit entre le bout de l lectrode et...

Page 18: ...r l usage avec ce soudeur Les lectrodes sont d sign es comme suit par l AWS American Welding Society 1 E 6013 TOUS USAGES Pour toutes positions d p t lisse et peu d claboussures Pour tous types d acie...

Page 19: ...ESSE DE D PLACEMENT La vitesse de d placement indique la vitesse que l lectrode est dirig e au long de la surface de soudage Voir Figure 9 Si la vitesse est trop rapide le cordon est troit et les ondu...

Page 20: ...ectrode 2 Mauvais raccordements au soudeur 1 Contact accidentel avec l objet de travail 2 Perte de courant caus par les v tements ou endroit de travail humides 1 Utilisation d un cordon prolongateur 2...

Page 21: ...ts La limitation ou exclusion pr c dente peut donc ne pas s appliquer C Les accessoires qui sont compris avec le produit et qui sont soumis l usure par l usage normal la r paration ou le remplacement...

Page 22: ...WC801100AV 7 lectrodes de soudure non illustr 1 16 po E6013 tube de 0 23 kg WE103501AV 5 64 po E6013 tube de 0 23 kg WE103002AV 1 16 po E7014 tube de 0 23 kg WE105502AV 5 64 po E7014 tube de 0 23 kg...

Page 23: ...Mod le WS0970 et WS0990 23 Fr Notes...

Page 24: ...Soudure Recouvrement un joint entre deux pi ces en chevauchement Tension au Repos OCV la tension entre l lectrode et le collier de mise la terre quand il n y a pas de flux de courant pas de soudage C...

Page 25: ...tado Si la soldadora est da ada o le faltan piezas comun quese con el distribuidor de Campbell Hausfeld m s cercano a su domicilio Requerimientos el ctricos Este equipo debe conectarse a un circuito d...

Page 26: ...antes de tratar de usarla Siempre apague la unidad y descon ctela antes de moverla a otro sitio Siempre conecte el cable de conexi n a tierra primero Cercieorese de que la pieza est conectada a tierra...

Page 27: ...inflamables o explosivos Tome todas las medidas de precauci n descritas en este manual para reducir las posibilidades de llamas o explosiones Mueva todos los materiales inflamables que se encuentren e...

Page 28: ...ea en Alto o Bajo Refi rase a la siguiente tabla por los valores de salida adecuados 7 Coloque el electrodo para comenzar a soldar c brase la cara con la m scara del casco o con la m scara de mano enc...

Page 29: ...orro aislante est da ado 2 Chequ e el cord n el ctrico y rep relo o reempl celo inmediatamente si est da ado 3 Chequ e el forro aislante del portaelectrodo y reemplace de inmediato las piezas que est...

Page 30: ...es chato y poroso vea la figura 9 El reborde aparece alto e irregular si la corriente es demasiado baja ANGULO PARA SOLDAR ste es el ngulo en el que mantiene el electrodo para soldar Si usa el ngulo...

Page 31: ...respectivos pa ses y ropa de protecci n para sacar la escoria Los residuos calientes le podr an ocasionar heridas a las personas que se encuentren en el rea de trabajo Una vez que haya terminado de s...

Page 32: ...circuito est sobrecargado La soldadora no hace ruido al encenderla La soldadora hace ruido pero no suelda La soldadora le da corrientasos peque os La soldadora se sobrecalienta se queman los fusibles...

Page 33: ...da os incidentales o consecuentes por lo tanto en tal caso esta limitaci n o exclusi n no es aplicable C Esta garant a no cubre aquellos accesorios que se desgastar n con el uso normal del producto la...

Page 34: ...16 in E6013 tubo de 0 5 lbs 227 g WE103501AV 2 mm 5 64 in E6013 tubo de 0 5 lbs 227 g WE103002AV 1 6 mm 1 16 in E7014 tubo de 0 5 lbs 227 g WE105502AV 2 mm 5 64 in E7014 tubo de 0 5 lbs 227 g WE10500...

Page 35: ...35 Sp Modelo WS0970 y WS0990 Notas...

Page 36: ...uestos en planos parale los Voltaje de circuito abierto el voltaje entre el electrodo y la pinza de conexi n a tierra de la soldadora cuando no hay flujo de corriente no se est soldando Esto determina...

Reviews: