background image

4

Operating Instructions

 

NB006401

www.chpower.com

Important Safety Instructions 

(Continued) 

 

Disconnect air  

  supply and release 

tension from the pusher before 
attempting to clear jams because 
fasteners can be ejected from the front 
of the tool. Personal injury may occur.

AIR SOURCE

a.  

Never connect to an air source that 
is capable of exceeding 200 psi. 

Over pressurizing the tool is able 
to result in bursting, abnormal 
operation, breakage of the tool or 
serious injury to persons. Use only 
clean, dry, regulated compressed air 
at the rated pressure or within the 
rated pressure range as marked on 
the tool. Always verify prior to using 
the tool that the air source has been 
adjusted to the rated air pressure or 
within the rated air-pressure range. 

b.  

Never use oxygen, carbon dioxide, 
combustible gases or any bottled 
gas as an air source for the tool. 

Such gases are capable of explosion 
and serious injury to persons. 

 

Do not  

  use any 

type of reactive gases, 
including, but not limited 
to, oxygen and combustible 
gases, as a power source. Use filtered, 
lubricated, regulated compressed air 
only. Use of a reactive gas instead of 
compressed air may cause the tool 
to explode which will cause death or 
serious personal injury.

 

Use  

  only a 

pressure-regulated 
compressed air source to limit 
the air pressure supplied to 
the tool. The regulated pressure must 
not exceed 110 psi. If the regulator 
fails, the pressure delivered to the 
tool must not exceed 200 psi. The tool 
could explode which will cause death or 
serious personal injury.

SAvE THESE INSTRUCTIONS 

DO NOT DISCARD

Operating Instructions

LUBRICATION

This tool requires lubrication before 
using the tool for the first time and 
before each use. If an inline oiler is 
used, manual lubrication through the 
air inlet 

is not

 required on a daily basis.

 

The work surface  

  can become 

damaged by excessive lubrication. 
Proper lubrication is the owner’s 
responsibility. Failure to lubricate the 
tool properly will dramatically shorten 
the life of the tool and void your 
warranty.

1.   Disconnect the air 

supply from the tool 
to add lubricant. 

2.   Turn the tool so the 

air inlet is facing up. Place 
4-5 drops of 30 W non-
detergent oil into air inlet. 
Do not use detergent 
oils, oil additives, or air- tool oils. 
Air tool oils contain solvents which 
will damage the tool's internal 
components. 

3.   After adding oil, run 

tool briefly. Wipe off 
any excess oil from 
the cap exhaust.

RECOMMENDED HOOKUP

The illustration below shows the 
recommended hookup for the tool.
1.   The air compressor 

must be able to 
maintain a minimum 
of 70 psi when the 
tool is being used. An inadequate air 
supply can cause a loss of power and 
inconsistent driving.

2.   An oiler can be 

used to provide oil 
circulation through 
the tool. A filter can 
be used to remove liquid and solid 
impurities which can rust or “gum 
up” internal parts of the tool. 

3.   Always use air supply hoses with 

a minimum working pressure 
rating equal to or greater than the 
pressure from the power source if a 
regulator fails, or 150 psi, whichever 
is greater. Use 1/4 inch air hose for 
runs up to 50 feet. Use 3/8 inch or 
greater air hoses for 50 foot run or 
longer.

4.   Use a pressure regulator on the 

compressor, with an operating 
pressure of 0 - 125 psi. A pressure 
regulator is required to control 
the operating pressure of the tool 
between 70 and 110 psi. 

O

CO

2

110 psi

150 psi or greater

70 psi 

Min.
110 psi 

Max.

Recommended Hookup

Quick Plug

Air Hose

Quick Plug (Optional)

Regulator

Filter

Quick 

Coupler

Lubricator

Quick 

Coupler 

(Optional)

OIL

Summary of Contents for IN704700AV

Page 1: ...o 100 nails no mar tip adjustable exhaust single cycle trigger quick clear nose and an adjustable depth of drive mechanism Unpacking After unpacking the unit inspect carefully for any damage that may have occurred during transit Make sure to tighten fittings bolts etc before putting unit into service Safety Guidelines This manual contains information that is very important to know and understand T...

Page 2: ... is able to cause the nail to be deflected and hit someone or cause the tool to react and result in a risk of injury to persons k Remove finger from the trigger when not driving fasteners Never carry the tool with finger on trigger the tool is able to fire a fastener Always remain in a firmly balanced position when using or handling the tool Avoid long extended periods of work with the tool Stop u...

Page 3: ...re the tool when it is idle out of reach of children and other untrained persons A tool is dangerous in the hands of untrained users f Maintain the tool with care Keep a cutting tool sharp and clean A properly maintained tool with sharp cutting edges reduces the risk of binding and is easier to control g Check for misalignment or binding of moving parts breakage of parts and any other condition th...

Page 4: ... for the first time and before each use If an inline oiler is used manual lubrication through the air inlet is not required on a daily basis The work surface can become damaged by excessive lubrication Proper lubrication is the owner s responsibility Failure to lubricate the tool properly will dramatically shorten the life of the tool and void your warranty 1 Disconnect the air supply from the too...

Page 5: ...Do not use the tool if it operates while lifted from the work surface Personal injury may result 7 Pull the trigger and depress the work contact element WCE against the work surface The nailer MUST NOT operate 8 Depress the Work Contact Element WCE against the work surface Pull the trigger The nailer MUST operate An improperly functioning tool must not be used Do not actuate the tool unless the to...

Page 6: ...personnel should repair the tool and they should use genuine Campbell Hausfeld replacement parts and accessories or parts and accessories which perform equivalently Assembly Procedure For Seals When repairing a tool the internal parts must be cleaned and lubricated Parker O lube or equivalent must be used on all o rings Each o ring must be coated with O lube before assembling A small amount of oil...

Page 7: ...drive channel 3 Dirt or damage prevent fasteners or pusher from moving freely in magazine 3 Clean magazine 4 Damaged pusher spring 4 Replace spring 5 Inadequate air flow to tool 5 Check fitting hose or compressor 6 Worn o rings on piston or lack of lubrication 6 Replace and lubricate o rings 7 Damaged o rings on trigger valve 7 Replace o rings 8 Air leaks 8 Tighten screws and fittings 9 Cap seal l...

Page 8: ...ructions provided in the owner s manual s supplied with product Accident purchaser s abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices are removed or altered this warranty is void D Normal adjustments which are explained in the owner s manual s provided with the product E Items or s...

Page 9: ...pide réglage de pénétration des clous Déballage Dès que l appareil est déballé l inspecter attentivement pour tout signe de dommages en transit S assurer de resserrer tous les raccords boulons etc avant de le mettre en service Directives de Sécurité Ce manuel contient de l information très importante qui est fournie pour la SÉCURITÉ et pour ÉVITER LES PROBLÈMES D ÉQUIPEMENT Rechercher les symboles...

Page 10: ...la gâchette lorsqu on n enfonce pas d attaches Ne jamais transporter l outil avec le doigt sur la gâchette car l outil pourrait déclencher l attache Toujours bien s équilibrer pendant la manipulation ou l utilisation de l outil Éviter d utiliser l outil pour une période de temps prolongée Cesser d utiliser l outil si l on ressent des douleurs dans les mains ou dans les bras Généralité a Pour rédui...

Page 11: ...rs non formés f Il faut entretenir l outil avec soin Gardez un outil de coupe tranchant et propre Un outil bien entretenu aux bords de coupe tranchants est moins susceptible de bloquer et est plus facile à contrôler g Vérifier pour tout signe de mauvais alignement ou grippage de pièces mobiles bris de pièces et toute autre condition qui pourrait affecter le fonctionnement de l outil Si l outil est...

Page 12: ... défaillance du régulateur la pression livrée à l outil ne doit pas dépasser 1 379 kPa L outil pourrait exploser ce qui pourrait mener à la mort ou à des blessures graves Conserver ces instructions Ne les jetez pas Mode d Emploi Graissage Cet outil exige le graissage avant son usage initial et avant chaque usage Si vous utilisez un graisseur en canalisation le graissage manuel à travers la prise d...

Page 13: ...isque de blessures 6 Oter la cloueuse de la surface de travail Le mécanisme de déclenchement par contact WCE doit redescendre à sa position initiale La cloueuse NE DOIT PAS FONCTIONNER Si l éjection d un clou se produit lorsqu on relève la cloueuse ne pas utiliser celle ci Il y a risque de blessures 7 Actionner la gâchette Appuyer le mécanisme de déclenchement par contact WCE sur la surface de tra...

Page 14: ...tes si l on utilise les mauvaises attaches Lors d une commande de pièces de rechange ou de clous préciser le numéro de pièce Réparation de la L OUTIL Seul le personnel dûment qualifié devrait réparer l outil en utilisant des pièces de rechange et des accessoires Campbell Hausfeld authentiques ou des pièces et accessoires qui fonctionnent de manière équivalente Méthode d assemblage pour les joints ...

Page 15: ...r 3 Saleté ou dommage qui empêche le fonctionnement libre des clous ou du poussoir dans le chargeur 3 Nettoyer le chargeur 4 Ressort de poussoir endommagé 4 Remplacer le ressort 5 Circulation d air insuffisante à la cloueuse 5 Inspecter le raccord tuyau ou le compresseur 6 Joint torique du piston usé ou manque de lubrification 6 Remplacer les joints torique Graisser 7 Joint torique de la soupape d...

Page 16: ...on abusive par l acheteur la négligence ou le manque de faire fonctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de sûreté Si ces appareils de sûreté sont enlevés ou modifiés la garantie sera annulée D Réglages normaux qui sont expliqués dans le s manuel s d utilisation accompagnant le produit E Articles ou services qui sont exig...

Page 17: ...o de un solo ciclo boca de despeje rápido y mecanismo clavador con profundidad ajustable Desempaque Al desempacar este producto revíselo con cuidado para cerciorarse de que esté en perfecto estado Cericiórese de apretar todas las conexiones pernos etc antes de comenzar a utilizar la unidad Medidas de Seguridad Este manual contiene información que es muy importante que sepa y comprenda Esta informa...

Page 18: ...No apunte con la herramienta hacia usted o hacia otra persona ya sea que contenga clavos o no j No clave ningún clavo encima de otro clavo Esto puede hacer que el clavo se desvíe y golpee a alguien o provocar que la herramienta reaccione y cause el riesgo de lesiones personales k Quite el dedo del gatillo cuando no esté clavando clavos Nunca lleve la herramienta con su dedo en el gatillo la herram...

Page 19: ...en muerte o graves lesiones personales No toque el gatillo a menos que se estén clavando sujetadores Nunca conecte la línea de aire a la herramienta ni mueva la herramienta cuando esté tocando el gatillo La herramienta podría expulsar un sujetador y producir la muerte o lesiones personales graves También coloque el protector del gatillo en la posición de seguro cuando no esté en uso Desconecte sie...

Page 20: ...de aire comprimido de presión regulada para limitar la presión de aire suministrada a la herramienta La presión regulada no debe exceder los 6 90 bar Si el regulador falla la presión transmitida a la herramienta no debe exceder los 13 79 bar La herramienta puede explotar lo cual puede ocasionar la muerte o graves lesiones personales GUARDE ESTAS INSTRUCCIONES NO LAS DESECHE Instrucciones de Funcio...

Page 21: ...arse o pegarse 4 Reconecte la clavadora a la fuente de suministro de aire 5 Presione el Elemento de Contacto de Trabajo contra la superficie de trabajo sin apretar el gatillo La clavadora NO DEBE OPERAR No use la herramienta si opera sin apretar el gatillo Se pueden producir lesiones personales 6 Remueva la clavadora de la superficie de trabajo El Elemento de Contacto de Trabajo tiene que volver a...

Page 22: ...a duración pueden disminuir si no se utilizan los sujetadores adecuados Cuando ordene piezas de repuesto o sujetadores especifique el número de la pieza Para reparar la herramienta La herramienta deberá ser reparada únicamente por personal calificado y deberán usar piezas de repuesto y accesorios originales Campbell Hausfeld o piezas y accesorios que funcionen de manera equivalente Para colocarle ...

Page 23: ...ebe limpiar el cargador 4 El resorte del mecanismo de impulso está dañado 4 Debe reemplazar el resorte 5 El flujo de aire hacia la herramienta es inadecuado 5 Chequée las conexiones la manguera o el compresor 6 El anillo en O del pistón está desgastado o le falta lubricación 6 Debe reemplazar los anillos en O y lubríquelos 7 Los anillos en O de la válvula del gatillo están dañados 7 Debe reemplaza...

Page 24: ...e del comprador o falta de operar el producto siguiendo las instrucciones del manual de instrucciones suministrado también debe incluir la desconexión o modificación de los instrumentos de seguridad Si dichos instrumentos de seguridad son desconectados la garantía quedaría cancelada D Los ajustes normales explicados en el los manual es suministrado s con el producto E Los artículos o servicios que...

Reviews: