background image

10

Operating Instructions

www.chpower.com

Limited Warranty

1.  DURATION: From the date of purchase by the original purchaser as follows: One Year.
2.  WHO GIVES THIS WARRANTY (WARRANTOR):  

Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400

3.  WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld 

compressor.

4.  WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: Any Campbell Hausfeld air compressor.
5.  WHAT IS COVERED UNDER THIS WARRANTY: Parts and Labor to remedy substantial defects due to material and workmanship during 

the first year of ownership with the exceptions noted below. Parts only to remedy substantial defects due to material and workmanship 
during remaining term of coverage with exceptions noted below.

6.  WHAT IS NOT COVERED UNDER THIS WARRANTY: 

A.  Implied warranties, including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED FROM THE DATE 

OF ORIGINAL PURCHASE AS STATED IN THE DURATION. If the compressor is used for commercial, industrial or rental purposes, the 
warranty will apply for ninety (90) days from the date of purchase. Two-stage compressors are not limited to a ninety (90) day warranty 
when used in commercial or industrial applications. Some States do not allow limitations on how long an implied warranty lasts, so the 
above limitations may not apply to you

B.  ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT, FAILURE, 

OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some States do not allow the exclusion or limitations of incidental or 
consequential damages, so the above limitation or exclusion may not apply to you.

C.  Any failure that results from an accident, purchaser’s abuse, neglect or failure to operate products in accordance with instructions 

provided in the owner’s manual(s) supplied with compressor.

D.  Pre-delivery service, i.e. assembly, oil or lubricants, and adjustment.
E.  Items or service that is normally required to maintain the product, i.e. lubricants, filters and gaskets, etc.
F.  Gasoline engines and components are expressly excluded from coverage under this limited warranty. The Purchaser must comply with 

the warranty given by the engine manufacturer which is supplied with the product

G.  Additional items not covered under this warranty:

1. Excluded items pertaining to All Compressors
  a.  Any component damaged in shipment or any failure caused by installing or operating unit under conditions not in accordance  

  with installation and operation guidelines or damaged by contact with tools or surroundings.

  b. Pump or valve failure caused by rain, excessive humidity, corrosive environments or other contaminants.
  c.  Cosmetic defects that do not interfere with compressor functionality.
  d. Rusted tanks, including but not limited to rust due to improper drainage or corrosive environments.
  e.  The following components are considered normal wear items and are not covered after the first year of ownership. Electric  

  motor, check valve, pressure switch, regulator, pressure gauges, hose, tubing, pipe, fittings and couplers, screws, nuts,  

 

  hardware items, belts, pulleys, flywheel, air filter and housing, gaskets, seals, oil leaks, air leaks, oil consumption or usage,   
  piston rings.

  f.  Tank drain valves.
  g. Damage due to incorrect voltage or improper wiring.
  h. Other items not listed but considered general wear parts.
  i.  Pressure switches, air governors, load/unload devices, throttle control devices and safety valves modified from factory  

 

  settings.

  j.  Damage from inadequate filter maintenance.
  k.  Induction motors operated with electricity produced by a generator.
2. Excluded items specific to Lubricated Compressors:
  a.  Pump wear or valve damage caused by using oil not specified.
  b. Pump wear or damage caused by any oil contamination.
  c.  Pump wear or damage caused by failure to follow proper oil maintenance guidelines, operation below proper oil level or    

  operation without oil.

H.  Labor, service call, or transportation charges after the first year of ownership of stationary compressors. Stationary compressors are 

defined as not including a handle or wheels.

7.  RESPONSIBILITIES OF WARRANTOR UNDER THIS WARRANTY: Repair or replace, at Warrantor’s option, compressor or component which is 

defective, has malfunctioned and/or failed to conform within duration of the warranty period.

8.  RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY:

A.  Provide dated proof of purchase and maintenance records.
B.  Call Campbell Hausfeld (800-543-6400) to obtain your warranty service options. Freight costs must be borne by the purchaser.
C.  Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s). 
D.  Repairs requiring overtime, weekend rates, or anything beyond the standard manufacturer warranty repair labor reimbursement rate.
E.  Time required for any security checks, safety training, or similar for service personnel to gain access to facility.
F.  Location of unit must have adequate clearance for service personnel to perform repairs and easily accessible.

9.  WHEN WARRANTOR WILL PERFORM REPAIR OR REPLACEMENT UNDER THIS WARRANTY: Repair or replacement will be scheduled and 

serviced according to the normal work flow at the servicing location, and depending on the availability of replacement parts.

This Limited Warranty applies in the U.S., Canada and Mexico only and gives you specific legal rights. You may also have other rights which 
vary from State to State or country to country.

Summary of Contents for IN630101AV

Page 1: ...nstructions Do Not Discard Caution indicates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury Notice indicates important information that if not followed m...

Page 2: ...n cause electrical arcs that will ignite a flammable gas or vapor Never operate or repair in or near a flammable gas or vapor Never store flammable liquids or gases in the vicinity of the compressor C...

Page 3: ...Figure 4 Lubrication This unit is shipped without oil Follow lubrication instructions before operating compressor Use oil shipped with the compressor Do not use regular automotive oil such as 10W 30...

Page 4: ...motor if it becomes overloaded If the overload protector is actuated the motor must be allowed to cool down for approximately 30 minutes before it will reset Installation Location It is extremely impo...

Page 5: ...used ASME Safety Valve Do not remove or attempt to adjust the safety valve Check the safety valve by performing the following steps 1 Plug the compressor in and run until shut off pressure is reached...

Page 6: ...aining tank 5 Air hose should be disconnected from compressor and hung open ends down to allow any moisture to drain 6 Compressor and hose should be stored in a cool dry place Technical Service For in...

Page 7: ..._________________________ ________________________________________________________________________________________________ _____________________________________________________________________________...

Page 8: ...off 1 Loose connections fittings tubing etc 1 Check all connections with soap and water solution Tighten or remove and apply pipe dope or pipe tape to the threads then reassemble 2 Open tank drain va...

Page 9: ...filter 2 Clean or replace filter 3 Circuit overloaded 3 Check for proper fuse use time delay fuse Disconnect other electrical appliances from circuit or operate compressor on its own branch circuit 4...

Page 10: ...re caused by rain excessive humidity corrosive environments or other contaminants c Cosmetic defects that do not interfere with compressor functionality d Rusted tanks including but not limited to rus...

Page 11: ...UCTIONS CONSERVER CES INSTRUCTIONS Ne pas jeter Directives de S curit Ce manuel contient de l information tr s importante qui est fournie pour la S CURIT et pour VITER LES PROBL MES D QUIPEMENT Recher...

Page 12: ...ctriques peuvent causer des arcs lectriques qui peuvent allumer un gaz ou une vapeur inflammable Ne jamais utiliser ou r parer le mod le pr s d un gaz ou d une vapeur inflammable Ne jamais entreposer...

Page 13: ...veau max sur le regard Le niveau d huile appropri est illustr la Figure 3 FILTRE D ASPIRATION Enfiler le filtre d aspiration dans l ouverture filet e sur le c t de la t te du compresseur tel qu illust...

Page 14: ...n limite R initialisation du moteur non illustr se trouve l int rieur du moteur Con u pour emp cher le moteur de surchauffer Le moteur a un protecteur de r initialisation automatique Pour r initialise...

Page 15: ...Inspecter le compresseur souvent et suivre les proc d s d entretien suivants pendant chaque utilisation du compresseur SOUPAPE DE S RET ASME Ne jamais enlever ni essayer d ajuster la soupape de s ret...

Page 16: ...eau de la soupape de s curit l aide de l autre main d tourner l air se d pla ant rapidement pour prot ger le visage 4 Vidanger le r servoir de toute condensation en ouvrant le robinet de vidange au fo...

Page 17: ...__________________ ________________________________________________________________________________________________ ____________________________________________________________________________________...

Page 18: ...se coupe 1 Raccordements d gag s raccords tuyaux etc 1 V rifier tous les raccordements avec de l eau savonneuse Resserrer ou retirer et appliquer aux filets un produit scellant ou de ruban pour filets...

Page 19: ...fusible utiliser un fusible retardement D brancher les autres appareils lectriques du circuit ou faire fonctionner le compresseur sur un circuit r serv 4 Utilisation de rallonge Calibre inad quat de...

Page 20: ...nt pas d effet sur le fonctionnement du compresseur d Les r servoirs rouill s y compris mais sans s y limiter la rouille caus e par la vidange incorrecte ou par un environnement corrosif e Les composa...

Page 21: ...TODAS LAS INSTRUCCIONES GUARDE ESTAS INSTRUCCIONES NO LAS DESECHE Medidas de Seguridad Este manual contiene informaci n que es muy importante que sepa y comprenda Esta informaci n se la suministramos...

Page 22: ...ompresor cerca de gases o vapores inflamables Nunca almacene l quidos o gases inflamables cerca del compresor Las piezas del compresor podr an estar calientes inclusive cuando la unidad est apagada 9...

Page 23: ...e aceite est ilustrado en la Figura 3 Filtro de entrada Enrosque el filtro de entrada de aire en la abertura roscada que se encuentra en uno de los lados del cabezal del compresor seg n se ilustra en...

Page 24: ...Para reiniciar una vez que se haya enfriado el motor coloque el interruptor en la posici n de apagado OFF y luego en la posici n de autom tico AUTO Este compresor est equipado con un protector de sobr...

Page 25: ...Enchufe el compresor y h galo funcionar hasta que se alcance la presi n de corte consulte Funcionamiento 2 Usando gafas de protecci n tire del anillo de la v lvula de seguridad para liberar la presi...

Page 26: ...ue halando el anillo de la v lvula de seguridad Use su otra mano para desviar el aire que se mueve a gran velocidad y evitar que le d en el rostro 4 Drene el tanque de la condensaci n abriendo la v lv...

Page 27: ...__________________ ________________________________________________________________________________________________ ____________________________________________________________________________________...

Page 28: ...aja cuando el compresor se apaga 1 Conexiones flojas conexiones tuber as etc 1 Revise todas las conexiones con una soluci n de agua y jab n Apriete o retire y aplique sellador o cintas para roscas lue...

Page 29: ...i rese de que est usando el fusible adecuado use un fusible de acci n retardada Desconecte los otros artefactos el ctricos del circuito o conecte el compresor a otro circuito 4 Uso del cable de extens...

Page 30: ...ncionamiento del compresor d Tanques oxidados incluyendo pero no limitado al xido debido al drenaje inadecuado u agentes corrosivos en el ambiente e Las siguientes piezas se consideran art culos sujet...

Page 31: ...Notes Notas 31 Operating Instructions Instructions d Utilisation Manual de Instrucciones HL5401 HX5400 Series...

Page 32: ...ucciones HL5401 HX5400 Series Date Maintenance Performed Repair Components Required Date Entretien Ex cut l ments de Remplacement Requis Fecha Maintenimiento Efectuado Componentes de Reparaci n Necesa...

Reviews: