Maintenance
See Maintenance Schedule on Page 17.
Disconnect, tag and lock out power source then release all
pressure from the system before attempting to install, service,
relocate or perform any maintenance.
In order to maintain efficient operation of the compressor system, check the
air filter and oil level before each use. The ASME safety valve should also be
checked daily (see Figure 10). Pull ring on safety valve and allow the ring to snap back
to normal position. This valve automatically releases air if the tank pressure exceeds
the preset maximum. If air leaks after the ring has been released, or the valve is stuck
and cannot be actuated by the ring, the ASME safety valve must be replaced.
Do not tamper with the ASME safety valve.
TANK
Never attempt to repair or modify a tank! Welding, drilling or
any other modifi cation will weaken the tank resulting in
damage from rupture or explosion. Always replace worn, cracked or damaged
tanks.
Drain liquid from tank daily.
The tank should be carefully inspected at a minimum of once a year. Look for cracks
forming near the welds. If a crack is detected, remove pressure from tank immediately
and replace.
Figure 10 - ASME Safety Valve
Operation (Continued)
Failure to install appropriate water / oil
removal equipment may result in damage to
machinery or workpiece.
AMBIENT OPERATING TEMPERATURE
The compressor is designed to operate in an ambient
temperature between 40° F and 100° F. At ambient temperatures
below 40° F, the unit must be heated up to at least 70° F before
start-up.
GUARDING
The belt guard provided must be
installed on the unit.
Never operate compressor without
a beltguard. This unit can start
automatically without warning. Personal injury or
property damage could occur from contact with moving parts.
All moving parts must be guarded. All electrical covers must be
installed before turning on the power.
DRAINING TANK
Condensate must be drained from the tank daily.