background image

3

CHN10450

www.chpower.com

Important Safety Instructions 

(Continued) 

e.  

Use safety equipment. 

A dust mask, 

non-skid safety shoes and a hard 
hat must be used for the applicable 
conditions. 

f.   

Always wear eye 
protection.

 

g.  

Always wear hearing 
protection when using 
the tool. 

Prolonged 

exposure to high intensity 
noise is able to cause 
hearing loss. 

h.  

Do not attach the hose or tool to 
your body. 

Attach the hose to the 

structure to reduce the risk of loss of 
balance if the hose shifts.

i.   

Always assume that the tool 
contains fasteners. 

Do not point 

the tool toward yourself or anyone 
whether it contains fasteners or not. 

j.   

  

Do not nail on 

  top of another 

nail. This is able to cause the nail to 
be deflected and hit someone, or 
cause the tool to react and result in a 
risk of injury to persons.

k. 

   

Remove finger 

  from the trigger 

when not driving fasteners. Never 
carry the tool with finger on trigger, 
the tool is able to fire a fastener.

 

Always remain in a 

  firmly balanced 

position when using or handling the 
tool.
 

Avoid long 

  extended periods of 

work with the tool. Stop using the tool 
if you feel pain in hands or arms.

TOOl USE aND CaRE

a.  

Use clamps or another practical way 
to secure and support the workpiece 
to a stable platform. 

Holding the 

work by hand or against the body is 
unstable and is able to lead to loss 
of control. 

b.  

Do not force the tool. 

Use the 

correct tool for the application. The 
correct tool will do the job better 
and safer at the rate for which the 
tool is designed. 

c.   

Do not use the tool if the switch 
does not turn the tool on or off. 

Any 

tool that cannot be controlled with 
the switch is dangerous and must be 
repaired. 

d.  

  

Disconnect the 

  tool from the air 

source before making adjustments, 
doing tool maintenance, clearing 
jams, leaving work area,loading, 
or unloading the tool.

 

Such 

precautionary measures reduce the 

risk of injury to persons.

e.  

Store the tool when it is idle out 
of reach of children and other 
untrained persons. 

A tool is 

dangerous in the hands of untrained 
users. 

f.   

Maintain the tool with care. 

Keep 

a cutting tool sharp and clean. A 
properly maintained tool, with sharp 
cutting edges reduces the risk of 
binding and is easier to control. 

g.  

Check for misalignment or binding 
of moving parts, breakage of parts, 
and any other condition that affects 
the tool’s operation. 

If damaged, 

have the tool serviced before using. 
Many accidents are caused by poorly 
maintained tools. There is a risk of 
bursting if the tool is damaged.

h.  

Use only those fasteners listed 
in the Accessories section of this 
manual. 

Fasteners not identified 

for use with this tool by the tool 
manufacturer are able to result in 
a risk of injury to persons or tool 
damage when used in this tool.

i.    Selecting an appropriate tool 

actuation system, taking into 
consideration the work application 
for which the tool is used.

 

Never use gasoline or other 
flammable liquids to clean 
the tool. Never use the tool in the 
presence of flammable liquids or gases. 
Vapors could ignite by a spark and 
cause an explosion which will result in 
death or serious personal injury.
 

Do 

  not 

remove, tamper with, 
or otherwise cause the 
trigger lock or trigger 
to become inoperable. 
Do not operate any 
tool which has been modified in a like 

fashion. Death or serious personal 
injury could result.

 

Do 

  not 

touch the trigger unless 
driving fasteners. Never 
attach air line to tool or 
carry tool while touching the trigger. 
The tool could eject a fastener which 
will result in death or serious personal 
injury. Also actuate the trigger lock to 
the safe position when not in use.
  

Always disconnect 
the tool from the power source 
when unattended, performing any 
maintenance or repair, clearing a jam, 
or moving the tool to a new location. 
Do not load the tool with fasteners 
when the trigger is depressed. The tool 
could eject a fastener causing death or 
serious personal injury.
  

 

Always fit tool with a 
fitting or hose coupling 
on or near the tool in 
such a manner that all 
compressed air in the tool is discharged 
at the time the fitting or hose coupling 
is disconnected. Do not use a check 
valve or any other fitting which allows 
air to remain in the tool. Death or 
serious personal injury could occur.
  

 

   

Never place hands or any 
other body parts in the 
fastener discharge area of 
the tool. The tool might eject a fastener 
and could result in death or serious 
personal injury.
  

 

Never carry the tool by 
the air hose or pull the 
hose to move the tool or 
a compressor. Keep hoses 
away from heat, oil and 
sharp edges. Replace any 
hose that is damaged, 
weak or worn. Personal injury or tool 
damage could occur.
 

Always assume the  

  tool contains 

fasteners. Respect the tool as a working 
implement; no horseplay. Always keep 
others at a safe distance from the work 
area in case of accidental discharge of 
fasteners. Do not point the tool toward 
yourself or anyone whether it contains 
fasteners or not. Accidental triggering 
of the tool could result in death or 
serious personal injury.

Summary of Contents for CHN10450

Page 1: ... help recognize this information observe the following symbols Danger indicates an imminently hazardous situation which if not avoided WILL result in death or serious injury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury Caution indicates a potentially hazardous situation which if not Locate model and date code on tool magazine and ...

Page 2: ... and injury to persons b Do not operate the tool in explosive atmospheres such as in the presence of flammable liquids gases or dust The tool is able to create sparks resulting in the ignition of the dust or fumes c Keep bystanders children and visitors away while operating the tool Distractions are able to result in the loss of control of the tool Personal Safety a Stay alert Watch what you are d...

Page 3: ...re caused by poorly maintained tools There is a risk of bursting if the tool is damaged h Use only those fasteners listed in the Accessories section of this manual Fasteners not identified for use with this tool by the tool manufacturer are able to result in a risk of injury to persons or tool damage when used in this tool i Selecting an appropriate tool actuation system taking into consideration ...

Page 4: ...f the tool Personal injury may occur Air Source a Never connect to an air source that is capable of exceeding 200 psi Over pressurizing the tool is able to result in bursting abnormal operation breakage of the tool or serious injury to persons Use only clean dry regulated compressed air at the rated pressure or within the rated pressure range as marked on the tool Always verify prior to using the ...

Page 5: ...hecking the Work Contact element WCE Check the operation of the Work Contact Element WCE trip mechanism before each use The WCE must move freely without binding through its entire travel distance The WCE spring must return the WCE to its fully extended position after being depressed Do not operate the tool if the WCE trip mechanism is not operating properly Personal injury may occur 1 Disconnect t...

Page 6: ...uipped with an adjustable direction exhaust deflector This is intended to allow the user to change the direction of the exhaust Simply twist the deflector to any direction desired CLEARING A JAM FROM THE TOOL 1 Disconnect the air supply from the nailer 2 Remove all nails from the magazine see Loading Unloading The Nailer Failure to remove all fasteners will cause the fasteners to eject from the fr...

Page 7: ...CHN10450 Notes 7 ...

Page 8: ...lt D51238K Paslode T125 F18 T200 F18 Porter Cable BN125 BN200 and Senco Finish Pro 15 18 Fasteners staples The following Campbell Hausfeld staples are available at local retail stores If you need help locating any item call customer service at 1 800 543 6400 Campbell Hausfeld staples meet or exceed astm Standard F1667 Model Length Wire Diameter Crown Size Point Finish Collation Staples Per Stick S...

Page 9: ...mper 2 Dirt in nose piece 2 Clean drive channel 3 Dirt or damage prevent fasteners or pusher from moving freely in magazine 3 Clean magazine 4 Damaged pusher spring 4 Replace spring 5 Inadequate air flow to tool 5 Check fitting hose or compressor 6 Worn o ring on piston or lack of lubrication 6 Replace and lubricate o rings 7 Damaged o ring on trigger valve 7 Replace o rings 8 Air leaks 8 Tighten ...

Page 10: ...lied with product Accident purchaser s abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices are removed or altered this warranty is void D Normal adjustments which are explained in the owner s manual s provided with the product E Items or service that are normally required to maintain ...

Page 11: ...ituation hasardeuse imminente qui RÉSULTERA en perte de vie ou blessures graves Avertissement indique une situation hasardeuse potentielle qui PEUT résulter en perte de vie ou blessures graves Attention indique une situation hasardeuse potentielle qui PEUT résulter en blessures Trouver le numéro de modèle et le code de date sur le chargeur et le corps de l outil et inscrire plus bas Nº du Modèle _...

Page 12: ...t de blessures aux personnes b Ne pas faire fonctionner l outil dans une atmosphère explosive comme en présence de liquides gaz ou poussières inflammables L outil peut produire des étincelles menant à une inflammation de poussières ou de fumées c Garder les spectateurs les enfants et les visiteurs loin en utilisant l outil Les distractions peuvent faire perdre le contrôle de l outil Sécurité perso...

Page 13: ...tible de bloquer et est plus facile à contrôler g Vérifier pour tout signe de mauvais alignement ou grippage de pièces mobiles bris de pièces et toute autre condition qui pourrait affecter le fonctionnement de l outil Si l outil est endommagé le réparer avant de l utiliser De nombreux accidents sont causés par des outils mal entretenus Il y a un risque d éclatement si l outil est endommagé h Utili...

Page 14: ...autorisées c Utiliser seulement les lubrifiants fournis avec l outil ou spécifiés par le fabricant Ne pas apporter de modifications à l outil sans d abord obtenir une approbation écrite de Campbell Hausfeld N utilisez pas d outil si les écrans ou protecteurs ont été enlevés ou altérés Ne pas utiliser l outil comme marteau Cela peut entraîner des blessures ou endommager l appareil Pour éviter l exp...

Page 15: ...ervice de l outil entre 414 et 690 kPa MODE SÉQUENTIEL UNIQUE La gâchette doit être tirée chaque fois qu une attache soit enfoncé L outil peut être actionnée en plaçant le mécanisme de déclenchement WCE contre la surface de travail et ensuite en tirant sur la gâchette La gâchette doit être relâchée afin de rajuster l outil avant d enfoncer un autre attache vÉrifier le mÉcanisme de dÉclenchement pa...

Page 16: ...qu à la profondeur recherchée 4 Après chaque réglage s assurer que le mouvement de la gâchette et du mécanisme de déclenchement par contact WCE puisse s effectuer vers le haut ou vers le bas sans difficulté ajustement de la direction d Échappement Cet outil est équipé d un déflecteur de sortie à direction ajustable Ceci permet le changement de direction de l échappement Orienter le déflecteur à la...

Page 17: ...outer quelque gouttes d huile sans détergent 30W ou l équivalent à travers la canalisation d air avant de faire l essai Entreposage L outil doit être rangé dans un denroit frais et sec Entretien Service Technique Pour des informations concernant le fonctionnement ou la réparation de ce produit composer le 1 800 543 6400 Attaches et Pièces de Rechange N utiliser que des clous Nº 18 de Campbell Haus...

Page 18: ...8K Paslode T125 F18 T200 F18 Porter Cable BN125 BN200 and Senco Finish Pro 15 18 Agrafes Les agrafes Campbell Hausfeld Brad ci dessous sont disponibles chez votre magasin local Pour de l assistance pour trouver n inporte quel pièce composer 1 800 543 6400 Les agrafes Campbell Hausfeld sont conformes ou supérieurs à la norme ASTM F1667 Modèle Longueur Calibre de Fil Taille de Tête Pointe Fini Colla...

Page 19: ...e du chassoir 3 Saleté ou dommage qui empêche le fonctionnement libre des clous ou du poussoir dans le chargeur 3 Nettoyer le chargeur 4 Ressort de poussoir endommagé 4 Remplacer le ressort 5 Circulation d air insuffisante à la cloueuse 5 Inspecter le raccord tuyau ou le compresseur 6 Joint torique du piston usé ou manque de lubrification 6 Remplacer les joints torique Graisser 7 Joint torique de ...

Page 20: ...busive par l acheteur la négligence ou le manque de faire fonctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de sûreté Si ces appareils de sûreté sont enlevés ou modifiés la garantie sera annulée D Réglages normaux qui sont expliqués dans le s manuel s d utilisation accompagnant le produit E Articles ou services qui sont exigés p...

Page 21: ...e LE OCASIONARIA la muerte o heridas de gravedad Ésto le indica que hay una situación que PODRIA ocasionarle la muerte o heridas de gravedad Ésto le indica que hay una situación que PODRIA ocasionarle heridas no muy graves Localice el modelo y el código de fecha en el cargador y el cuerpo de la herramienta y regístrelo debajo Modelo Nº ______________________ Código de fecha ________________ Conser...

Page 22: ...SIONES GRAVES Área de trabajo a Mantenga el área de trabajo limpia y bien iluminada Los bancos desordenados y las áreas oscuras aumentan el riesgo de choque eléctrico incendio y lesiones personales b No haga funcionar la herramienta en entornos explosivos como por ejemplo cuando haya polvo líquidos o gases inflamables La herramienta puede crear chispas Instrucciones de Seguridad Importantes INSTRU...

Page 23: ...cionar ninguna herramienta que haya sido modificada de manera similar Eso puede resultar en muerte o graves lesiones personales No toque el gatillo a menos que se estén clavando sujetadores Nunca conecte la línea de aire a la herramienta ni mueva la herramienta cuando esté tocando el gatillo La herramienta podría expulsar un sujetador y producir la muerte o lesiones personales graves También coloq...

Page 24: ...alguna pieza dañada o tiene fugas de aire DEJE de trabajar y repárela antes de usarla o podría ocasionarle heridas graves Evite usar la herramienta cuando el depósito está vacío Ésto podría acelerar su desgaste Limpie y chequee todas las mangueras de suministro de aire y conexiones antes de conectar la herramienta al compresor Reemplace las mangueras y conexiones que estén dañadas o desgastadas El...

Page 25: ...ta 3 Use mangueras de aire de 6 4 mm 1 4 in diseñadas para presiones mínimas de trabajo de 10 34 bar Use mangueras de aire de 9 5 mm 3 8 in si la longitud de las mismas es de 15m ó más Para un mejor rendimiento instálele a la herramienta un conector rápido de 9 5 mm 3 8 in roscas de 6 4 mm 1 4 in NPT cuyo diámetro interno sea de 8 mm 0 315 in y un acoplador rápido de 9 5 mm 3 8 in a la manguera de...

Page 26: ...viene equipada con un mecanismo clavador de profundidad ajustable Esto le permite al usuario determinar a qué profundidad se va a clavar en la superficie de trabajo 1 Ajuste la presión de operación a aquella que usará con regularidad para clavar los sujetadores No exceda la presión de 6 90 bar 2 Para dirigir la herramienta gire la rueda C hacia la derecha hasta el punto deseado 3 Para clavar el su...

Page 27: ...nte al equipo original El rendimiento de las herramientas la seguridad y la duración pueden verse reducidos Cuando ordene partes de repuesto o sujetadores especifique el número de la parte Para reparar la herramienta La herramienta debe ser reparada únicamente por personal calificado y deben usar piezas de repuesto y accesorios originales Campbell Hausfeld o piezas y accesorios que funcionen de ma...

Page 28: ... Porter Cable BN125 BN200 and Senco Finish Pro 15 18 Sujetadores grapas Estas grapas para acabado de Campbell Hausfeld los puede comprar en su tienda más cercana Si necesita ayuda para encontrar un artículo comuníquese al 1 800 543 6400 Las grapas de Campbell Hausfeld cumplen o exceden las especificaciones Federales FF N 105B Modelo Longitud Calibre de la Grapa Corona Punta Acabodo Unión Grapes po...

Page 29: ...n el cargador 3 Debe limpiar el cargador 4 El resorte del mecanismo de impulso está dañado 4 Debe reemplazar el resorte 5 El flujo de aire hacia la herramienta es inadecuado 5 Chequée las conexiones la manguera o el compresor 6 El anillo en O del pistón está desgastado o le falta lubricación 6 Debe reemplazar los anillos en O Lubríquelos 7 Los anillos en O de la válvula del gatillo están dañados 7...

Page 30: ... comprador o falta de operar el producto siguiendo las instrucciones del manual de instrucciones suministrado también debe incluir la desconexión o modificación de los instrumentos de seguridad Si dichos instrumentos de seguridad son desconectados la garantía quedaría cancelada D Los ajustes normales explicados en el los manual es suministrado s con el producto E Los artículos o servicios que son ...

Page 31: ...Notes Notas CHN10450 ...

Page 32: ...Notes Notas Operating Instructions Instructions d utilisation Manual de Instrucciones de Operación ...

Reviews: