background image

compressed air may cause the tool 
to explode which will cause death 
or serious personal injury.

 Use only 

a pressure-regulated 
compressed air source 
to limit the air pressure 
supplied to the tool. The regulated 
pressure must not exceed 90 PSI. 
If the regulator fails, the pressure 
delivered to the tool must not 
exceed 200 PSI. The tool could 
explode which will cause death or 
serious personal injury.

SAVE THESE INSTRUCTIONS

DO NOT DISCARD 

4

Operating Instructions

Important Safety Instructions 
(Continued) 

b.  

When servicing a tool, use only 
identical replacement parts. Use 
only authorized parts. 

c.   

Use only the lubricants supplied 
with the tool or specified by the 
manufacturer. 

 

Do not make any 

 modifi cations to 

the tool without fi rst obtaining written 
approval from Campbell Hausfeld. Do 
not use the tool if any shields or guards 
are removed or altered. Do not use the 
tool as a hammer. Personal injury or 
tool damage may occur.

AIR SOURCE

a.  

Never connect to an air source that 
is capable of exceeding 200 PSI. 

Over pressurizing the tool is able 
to result in bursting, abnormal 
operation, breakage of the tool or 
serious injury to persons. Use only 
clean, dry, regulated compressed air 
at the rated pressure or within the 
rated pressure range as marked on 
the tool. Always verify prior to using 
the tool that the air source has been 
adjusted to the rated air pressure or 
within the rated air-pressure range. 

b.  

Never use oxygen, carbon dioxide, 
combustible gases or any bottled 
gas as an air source for 
the tool. 

Such gases are 

capable of explosion and 
serious injury to persons. 

 Do 

not

 use any 

type of reactive gases, including, 
but not limited to, oxygen and 
combustible gases, as a power 
source. Use fi ltered, lubricated, 
regulated compressed air only. 
Use of a reactive gas instead of 

OPERATING INSTRUCTIONS

 LUBRICATION

Proper lubrication is the owner’s 
responsibility. Failure to lubricate the air 
tool properly will dramatically shorten 
the life of the tool and will void the 
warranty.

 

This air tool 

 requires 

lubrication before the initial 
use and before and after each 
additional use.

Air tools require lubrication throughout 
the life of the tool. Air tool oil is 
recommended because this oil cleans, 
lubricates and inhibits rust all in one 
step. Use Campbell Hausfeld air tool oil 
ST127001AV or equivalent ISO grade 32 
oil.

 

After an air tool 

 has been 

lubricated, oil will discharge 
through the exhaust port during 
the fi rst few seconds of operation. 
Thus, the exhaust port must be 
covered with a towel before 
applying air pressure. Failure to 
cover the exhaust port can result in 
serious injury.

1.   Disconnect tool from air supply.

2.   Turn tool upside down.

3.   While pressing trigger, apply 5 - 10 

drops of oil in the air inlet.

4.   Connect the air tool to the air supply 

and cover the exhaust port with a 
towel. Run the air tool for 7 to 10 
seconds. Oil will discharge from the 
exhaust port when air pressure is 
applied. 

RECOMMENDED HOOKUP

The illustration below shows the 
recommended hookup for the tool.

1.   The air compressor 

must be able to 
maintain a minimum 
of 60 PSI when the 
tool is being used. 
An inadequate air supply can cause 
a loss of power and inconsistent 
driving.

2.   An oiler can be 

used to provide oil 
circulation through 
the tool. A filter can 
be used to remove 
liquid and solid impurities which can 
rust or “gum up” internal parts of 
the tool. 

3.   Always use air supply hoses with 

a minimum working pressure 
rating equal to or greater than the 
pressure from the power source if a 
regulator fails, or 200 PSI, whichever 
is greater. Use 1/4 inch air hose for 

200 PSI or greater

3/8 inch I.D.

 Recommended Hookup

Quick Plug

Quick 
Coupler

Air Hose

Quick Plug 
(Optional)

Quick 
Coupler 
(Optional)

Regulator

Lubricator

Filter

60 PSI 
Min.

90 PSI 
Max.

www.campbellhausfeld.com

O

CO

2

90 PSI

Summary of Contents for AT0510

Page 1: ...f not avoided WILL result in death or serious injury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury Caution indicates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury Notice indicates important information that if not followed may cause damage to equipment NOTE Information that requires s...

Page 2: ...and gloves away from moving parts Loose clothes jewelry or long hair increases the risk of injury to persons as a result of being caught in moving parts c Avoid unintentional starting Be sure the switch is off before connecting to the air supply Do not carry the tool with your finger on the switch or connect the tool to the air supply with the switch on 2 Operating Instructions Important Safety In...

Page 3: ...ort the workpiece to a stable platform Holding the work by hand or against the body is unstable and is able to lead to loss of control b Do not force the tool Use the correct tool for the application The correct tool will do the job better and safer at the rate for which the tool is designed c Do not use the tool if the switch does not turn the tool on or off Any tool that cannot be controlled wit...

Page 4: ...NG INSTRUCTIONS LUBRICATION Proper lubrication is the owner s responsibility Failure to lubricate the air tool properly will dramatically shorten the life of the tool and will void the warranty This air tool requires lubrication before the initial use and before and after each additional use Air tools require lubrication throughout the life of the tool Air tool oil is recommended because this oil ...

Page 5: ...nch I D hose Hoses longer than 50 feet should have a 1 2 inch I D NOTE It is not recommended to install a quick coupler between the air tool and the leader whip hose Never carry a tool by the hose or pull the hose to move the tool or a compressor Keep hoses away from heat oil and sharp edges Replace any hose that is damaged weak or worn USER MAINTENANCE INSTRUCTIONS TECHNICAL SERVICE For informati...

Page 6: ...ure drops and reduces the tool power Directly connect the hoses together 6 Worn rotor blade in motor 6 Replace rotor blade 7 Worn ball bearing in motor 7 Remove and inspect bearing for rust dirt and grit or worn race Replace or clean and regrease bearing with bearing grease Moisture blowing out of tool 1 Water in tank 1 Drain tank Oil tool and run until no water is evident Oil tool again and run 1...

Page 7: ...7 AT0510 TL0501 Notes www campbellhausfeld com ...

Page 8: ...ded in the owner s manual s supplied with product Accident purchaser s abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices are removed or altered this warranty is void D Normal adjustments which are explained in the owner s manual s provided with the product E Items or service that ar...

Page 9: ...hasardeuse potentielle qui PEUT résulter en blessures Avis indique de l information importante pour éviter le dommage de l équipement REMARQUE L information qui exige une attention spéciale Importantes instructions de sécurité INSTRUCTIONS PORTANT SUR UN RISQUE D INCENDIE UN CHOC ÉLECTRIQUE OU DES BLESSURES AUX PERSONNES Ce manuel contient des informations concernant la sécurité le fonctionnement ...

Page 10: ...tements amples Attacher les cheveux longs Garder les cheveux les vêtements et les gants loin des pièces mobiles Les vêtements amples les bijoux ou les cheveux longs augmentent le risque de blessures si quelque chose se prend dans les pièces mobiles c Éviter tout démarrage accidentel S assurer que l interrupteur est en position d arrêt off avant de 2 Fr Instructions d utilisation Importantes instru...

Page 11: ...liser De nombreux accidents sont causés par des outils mal entretenus Il y a un risque d éclatement si l outil est endommagé h Utiliser seulement des accessoires identifiés par le fabricant pour le modèle précis d outil Utiliser un accessoire non prévu pour une utilisation avec le modèle précis d outil augmente le risque de blessures pour les personnes i Choisir un système d activation de l outil ...

Page 12: ...ssion d air fournie à l outil La pression contrôlée ne doit pas dépasser 621 kPa S il y a une défaillance du régulateur la pression livrée à l outil ne doit pas dépasser 1 379 kPa L outil pourrait exploser ce qui pourrait mener à la mort ou à des blessures graves CONSERVER CES INSTRUCTIONS NE LES JETEZ PAS MODE D EMPLOI GRAISSAGE L utilisateur est responsable du graissage correct Un graissage inco...

Page 13: ...r obtenir un bon rendement et une meilleure fonctionnalité utiliser un tuyau de 3 8 po de diamètre intérieur Les tuyaux de plus de 15 24 m de long doivent avoir un diamètre intérieur de 1 2 po REMARQUE Il n est pas recommandé de monter un coupleur rapide entre l outil pneumatique et l amorce fléchie du tuyau Ne jamais transporter un outil en le tenant par le tuyau ni tirer sur celui ci pour déplac...

Page 14: ...ir peuvent nécessiter un diamètre intérieur de tuyau d au moins 1 2 po suivant la longeur totale du tuyau 5b Ne pas utiliser plusieurs tuyaux reliés ensemble au moyen de raccords rapides Cela provoque des chutes de pression supplémentaires et réduit la puissance de l outil Brancher les tuyaux directement les uns aux autres 6 Usure d une pale de rotor du moteur 6 Remplacer la pale du rotor 7 Usure ...

Page 15: ...7 Fr AT0510 TL0501 Notes ...

Page 16: ... utilisation abusive par l acheteur la négligence ou le manque de faire fonctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de sûreté Si ces appareils de sûreté sont enlevés ou modifiés la garantie sera annulée D Réglages normaux qui sont expliqués dans le s manuel s d utilisation accompagnant le produit E Articles ou services qui...

Page 17: ...reconocer los siguientes símbolos Ésto le indica que hay una situación inmediata que LE OCASIONARIA la muerte o heridas de gravedad Ésto le indica que hay una situación que PODRIA ocasionarle la muerte o heridas de gravedad Ésto le indica que hay una situación que PODRIA ocasionarle heridas no muy graves Ésto le indica una información importante que de no seguirla le podría ocasionar daños al equi...

Page 18: ... las etiquetas y el manual de la herramienta Si no respeta las advertencias los riesgos y las recomendaciones eso podría resultar en la MUERTE o en LESIONES GRAVES ÁREA DE TRABAJO a Mantenga el área de trabajo limpia y bien iluminada Los bancos lesiones personales como resultado de quedar atrapados en las piezas móviles c Evite que se encienda accidentalmente Asegúrese de que el interruptor esté e...

Page 19: ...nta Mantenga una herramienta para cortar afilada y limpia Una herramienta mantenida adecuadamente con bordes de corte afilados reduce el riesgo de atascarse y es más fácil de controlar g Verifique que las piezas móviles no estén desaliñadas ni adheridas que no haya piezas rotas y que no exista ningún otro problema que afecten el funcionamiento de la herramienta Si está dañada haga que le realicen ...

Page 20: ...o del rango de presiones indicadas b No use nunca oxígeno dióxido de carbono gases combustibles o ningún gas en botellas como suministro de aire para la herramienta Tales gases puede explotar y causar graves lesiones personales No use ningún tipo de gas reactivo incluyendo pero no limitado a oxígeno y gases combustibles como fuente de energía Use sólo aire comprimido filtrado lubricado y regulado ...

Page 21: ...s o mangueras de aire que sean demasiado pequeñas puede crear una caída de presión y reducir la potencia de la herramienta Se recomienda una conexión de 9 5 mm 3 8 pulg de diámetro interno con roscas NPT de 6 4 mm 1 4 pulg La mayoría de los compresores se envían con una manguera corta de 6 4 mm 1 4 pulg de diámetro interno Para un rendimiento adecuado y una mayor conveniencia utilice una manguera ...

Page 22: ...s herramientas que utilizan grandes volúmenes de aire pueden requerir una manguera con un diámetro interno de 12 7 mm 1 2 pulg o mayor dependiendo del largo total de la manguera 5b No utilice varias mangueras conectadas entre sí con conexiones de conexión rápida Esto provoca caídas de presión adicionales y reduce la potencia de la herramienta Conecte las mangueras entre sí directamente 6 Paleta de...

Page 23: ...7 Sp AT0510 TL0501 Notas ...

Page 24: ...tes abusos por parte del comprador o falta de operar el producto siguiendo las instrucciones del manual de instrucciones suministrado también debe incluir la desconexión o modificación de los instrumentos de seguridad Si dichos instrumentos de seguridad son desconectados la garantía quedaría cancelada D Los ajustes normales explicados en el los manual es suministrado s con el producto E Los artícu...

Reviews: