Operation and maintenance instructions
Series PRE proportional pressure regulator
Analog /preset version
5000024670
Ver. 01
22
o
Family name
: description of device type
o
Firmware
: firmware version
o
Last transmission
: date and time of last data received
o
Device status
: global state of device
o
Operational status
: operational status of device that can either be “work” if the
target pressure is received by the command signal (analog input or digital inputs)
or “manual” if the target pressure is received by UVIX.
o
Connection
: indicates if the device is transmitting or, more precisely, if the UVIX is
receiving data from it. The indication is given by the color of the dot that turns
green if the device is connected or red if it is not connected.
o
Under the device picture the “Configuration” command is located. Via this
command it is possible to open the configuration window of the selected device
12.1.2.
Details
This section is divided into 3 sub-sections and lists specific information about selected device.
VARIABLES
This sub-section lists all variables sended from device to UVIX, including those related to Coil
Vision if the device is setted with advanced diagnostic.
•
Hardware Version: device hardware version.
•
Product Code: commercial code of the device.
•
Command signal: reference signal used by the device.
•
Temperature: device temperature value.