Operation and maintenance instructions
Series PRE proportional pressure regulator
Analog /preset version
5000024670
Ver. 01
19
•
For the electrical connection the following cable types are available:
CODE
DESCRIPTION
CS-LF08HB-C200 co-moulded connector M12 8 pole, female, straight with 2-metre cable unshielded
CS-LF08HB-C500 co-moulded connector M12 8 pole, female, straight with 5-metre cable unshielded
CS-LR08HB-C200 co-moulded connector M12 8 pole, female, bend with 2-metre cable unshielded
CS-LR08HB-C500 co-moulded connector M12 8 pole, female, bend with 5-metre cable unshielded
G11W-G12W-2
Micro USB cable (it may be used during the configuration phase)
10.
CoilVision
With the integrated CoilVision technology the proportional regulator is able to
constantly monitor the operation of the coils inside it and prevent any malfunctions.
Depending on the model chosen, the proportional regulator can have three different levels of
diagnostics:
•
Without diagnosticc: the CoilVision technology isn’t implemented.
•
Basic diagnostics: CoilVision technology is active and will advice the user when the coils are
nearing the end of their life cycle
•
CoilVision diagnostics: CoilVision technology is active and, in addition to advice the user
when the coils are nearing the end of their life cycle, constantly sends information about
their current health status to the UVIX environment.
11.
Digital output
The digital output (OUT signal, pin 8) is a 0-24V digital signal. Through the UVIX configuration
software it is possible to set the logic of this output:
•
Active – high level: if the output is activated, its value is brought to a high logic level.
•
Active – low level: if the output is activated, its value is brought to a low logic level.