14
Brine Master
®
English
14.1 - To clean your refractometer, turn the 5/16” push to
connect valves to the off position. Then pull the pin on the
front and twist the body of the refractometer counter clockwise
to remove it. Clean the lens and the inside body removing
any debris. To reinstall, pull the pin
and turn the body clockwise. Make
certain the O-ring is seated correctly
when reassembling. Lastly reopen
your 5/16” push to connect valves.
14.2 - Turn valves to positions in the
following image to drain the hoses and
fittings.
14.3 - Remove drain plug from bottom of pump
to allow liquid to drain.
14.4 - To drain the salt hopper, connect your suction hose
onto the additive port and insert the suction end (with a foot
strainer attached) into the salt hopper. Your discharge hose
needs to be connected to an appropriate holding vessel that
will contain the out of spec brine from the
salt hopper. Once the hopper is mostly
drained, the 3” discharge valve can be
opened and remaining debris can be
drained into a skid steer bucket.
MAINTAINING
Instruction References