15
Version 1.2
English
CONDITION
REMEDY
Reduced flow rate
1) Check for a blockage in the filter
screen.
Hopper is backing up
or overflowing
1) Ensure there is no blockage on
internal hopper screen.
2) Clean debris or salt away from the
screen.
3) Make sure you are not filling your
orange brining tank over 600 gallons.
Pump will not turn on
1) Check breakers and relays. Reset if
needed.
2) Check adequate power supply.
3) Verify wiring is in good condition.
Bottom clean out on
hopper drain will not
flow
1) Place a large cleanout vessel (ie:
skidsteer bucket) underneath the 3”
clean out valve and remove compacted
salt or debris by inserting a garden
hose up into hopper cleanout valve.
Salinity measuring
instrument is not
reading or reading
inaccurately
1) Ensure that the push to connect
valves are in the open position to allow
flow.
2) Check that the salinity measuring
instrument is cleaned
3) Refer to salinity measuring
instrument manual for further
troubleshooting.
TROUBLESHOOTING