23
16. Mount the combustion air supply (flexible hose,
Ø 125 mm) with the quick-action clamp on the
lower connector.
18. Carefully insert the interior lining again and lay on
the front sealing fleece.
15. ... and adjust it to a height of 285 mm using the
adjustment screws from the upper edge of the floor
panel up to the lower edge of the body.
17. Insert the outer fire clay sleeve with the sealing
fleece and remount the fire clay retaining ring.
19. Place on the upper fire clay ring.
285 mm
20. Align the masonry stove body with a spirit level and
readjust if necessary.