11
Fig. 5. Declaration to type label.
4 5
1
10
9
8
7
6
2
11
3
12 13
U
G
(U1)
U
S
(U2)
Camille Bauer AG
Switzerland
SINEAX G 537
Ord: 123123 / 123 /1
–120...120 °el
110V 50 Hz
85-230V AC/DC
50/60 Hz 3 VA
U
G
4...20mA
+
–
+
–
U
S
0,5
3,7
Output
Output signal
Measuring inputs
Power supply
6. Commissioning and maintenance
Switch on the power supply and the measuring inputs. It is
possible during the operation to disconnect the output line and
to connect a check instrument, e.g. for a functional test.
No maintenance is required.
7. Releasing the transducer
Release the transducer from a top-hat rail as shown in
Fig. 6.
Fig. 6
8. Dimensional drawing
70
69.1
114.1
112.5
4 5
1
10
9
8
7
6
2
11
3
12 13
Fig. 7. Housing
P13/70
clipped onto a top hat rail (35
×
15 mm or
35
×
7.5 mm, acc. to EN 50 022).
9. Instruments admissions
Germanischer Lloyd
Type approval certifi cate: 12 261-98 HH
CSA approved for USA and Canada
fi le-nr. 204767
FCC Compliance and Canadian DOC Statement
This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to both part
15 of the FCC Rules and the radio interference regulations
of the Canadian Department of Communications: These
limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses
and can radiate radio frequency energy and, if not instal-
led and used in accordance with the instruction manual,
may cause harmful interference to radio communications.
Operation of this equipment in a residential area is like to
cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Symbol
Meaning
Double insulation, device of protection class 2
3,7
Test voltage of insulation according to IEC60051:
AC 3.7 kV
0,5
Class icon to the EN60688:
error limit 0.5% of span
CE conformity mark. The device fulfi lls the require-
ments of the applicable EC directives.
CSA approved for USA and Canada
fi le-nr. 204767
Germanischer Lloyd
Type approval certifi cate: 12 261-98 HH
Caution!
General hazard point.
Read the operating instructions.
General symbol: Input
General symbol: Output
General symbol: Power supply
CAT III
Measurement category CAT III for current and vol-
tage inputs