EMC_SPEC040_CLCR.doc
Rev. E
–
2021 10 18
44/63
Install & Operating Manual
CleanSeal V3
Front Plate Operation for CleanSeal CL
The front plate locking system allows for fast & easy access without tools (no screws).
•
To unlock, use the Quick Access Card
(included with each housing)
or any other plastic blade <= 2mm
DO NOT use a metal tool as you might
scratch the coating and thus compromise
corrosion protection.
•
To lock, simply close the front plate.
•
100% safe lock against accidental opening
(e.g. during cleaning).
PLEASE NOTE:
For revalidation of the filter, the front plate can stay in place.
However, we recommend taking it out for filter change.
Removing or installing the front plates requires full 90° opening.
A minimum intervention space beneath the housing needs to be free
from obstructions of any kind.
Custom solutions are available if this cannot be ensured.
➔
Please contact your Camfil representative
PLEASE NOTE:
Front Plates are fully interchangeable between different models.
To remove
open 90° and LIFT to unhook
3P3
3P6
327
632
4P4
5P5
6P6
9P6
632
937
9P9
11P5
530
1130
12P6
632
1242
632
937
C
lea
n
S
ea
l
S
iz
es
Minimum Intervention Space
[mm]
327
508
530
Short Side (SS) down
Long Side (LS) down