EMC_SPEC040_CLCR.doc
Rev. E
–
2021 10 18
39/63
Install & Operating Manual
CleanSeal V3
Installation Validation before Startup
IMPORTANT:
Verify probe state and alignment
The probe will be inaccessible without breaking
confinement once the HEPA filter is installed in
the housing.
After installation or intervention or after probe removal and
re-installation, perform a running test to check :
•
Probe movement must be smooth and precise over the full support length.
•
End positions must be reached without blockage
•
The probe must not touch the module frame in any position (alignment).
•
The connection tube must not stretch or collapse at any point, nor exceed the probe level.
•
Scan support rails and drive screw must be free from dirt, surface damage or deformation
IMPORTANT:
Use only the Camfil qualified MIP driver
to operate the system
(
see also § 10.4.7
DO NOT use general purpose electrical
screwdrivers !
Exceeding drive torque will damage the flexishaft and require
breaking confinement or access to the technical area for
replacement.
WARNING:
Danger of injury due to improper commissioning and operation
During normal operation, the scanning system will be safely inaccessible
behind the installed filter.
During testing without filter after installation or maintenance, use precaution.
•
Handle the probe with care.
•
Ensure that components are properly assembled and aligned
•
Ensure using only qualified drive equipment
•
Ensure the entire scanning area is free from obstruction or foreign bodies
•
Do not reach into the housing when the system is moving or when a driver is connected
to the interface in the box.