LEFM 3xxCi User Manual
IB1406 Rev 12
Section 7
Page 53
February 2017
Figure 7.6 Disassembly Views for removing MXR
1.
Loosen the two setscrews on the top of the enclosure. Unscrew and remove the top lid of the
enclosure. Note – this may require disconnecting any conduit attached to the transmitter (in order
to spin the head).
Use proper grounding straps on personnel before handling any circuit boards.
2.
Loosen the transducer wires connector flanges (two connectors) and disconnect both connectors.
Push the transducer wires/connectors to the side so that the MXR can be removed. Remove
ribbon cable from P1 connector.
3.
Remove the MXR board fasteners (qty 4). Grasp the edges of the MXR and gently pull to lift it
from the enclosure.
4.
Remove the new MXR from its packaging. Place the old MXR into this packaging for proper
storage.
5.
Align the MXR onto its standoffs in the top lid of the enclosure and reinstall the four screws that
were removed.
CAUTION