LEFM 3xxCi User Manual
IB1406 Rev 12
Section 3
Page 23
August 2017
Table 3.1 LEFM 380Ci-R Transducer and RTD Terminations (See Figure 3.2)
Transducer Cable
Identification
G3 J-Box Termination
Meter Body Junction Box
Wire Name
Terminal
Pin
Device
Pin
RTD (+)
TB5
1
1B - Upstream JBOX-TB3
9
RTD (-)
2
10
RTD (+)
3
11
RTD (-)
4
12
1 UP (+)
TB1
1
1A - Upstream JBOX-TB1
1
SHIELD
2
-
1 UP (-)
3
2
2 UP (+)
4
1A - Upstream JBOX-TB1
3
SHIELD
5
-
2 UP (-)
6
4
3 UP (+)
7
1A - Upstream JBOX-TB1
5
SHIELD
8
-
3 UP (-)
9
6
4 UP (+)
10
1A - Upstream JBOX-TB1
7
SHIELD
11
-
4 UP (-)
12
8
5 UP (+)
TB3
1
2A - Upstream JBOX-TB1
1
SHIELD
2
-
5 UP (-)
3
2
6 UP (+)
4
2A - Upstream JBOX-TB1
3
SHIELD
5
-
6 UP (-)
6
4
7 UP (+)
7
2A - Upstream JBOX-TB1
5
SHIELD
8
-
7 UP (-)
9
6
8 UP (+)
10
2A - Upstream JBOX-TB1
7
SHIELD
11
-
8 UP (-)
12
8
1 DN (+)
TB2
1
1B - Upstream JBOX-TB1
1
SHIELD
2
-
1 DN (-)
3
2
2 DN (+)
4
1B - Upstream JBOX-TB1
3
SHIELD
5
-
2 DN (-)
6
4
3 DN (+)
7
1B - Upstream JBOX-TB1
5
SHIELD
8
-
3 DN (-)
9
6
4 DN (+)
10
1B - Upstream JBOX-TB1
7
SHIELD
11
-
4 DN (-)
12
8
5 DN (+)
TB4
1
2B - Upstream JBOX-TB1
1
SHIELD
2
-
5 DN (-)
3
2
6 DN (+)
4
2B - Upstream JBOX-TB1
3
SHIELD
5
-