27
Table 4-5. Troubleshooting Chart
(Continued)
High
Primary
Orifice partially restricted
Clean out or replace
Indication
or too small
Piping from
Leak in LP side piping
Repair leaks
Primary Element
to DPU
Bellows Unit
Gas trapped (liquid service)
in LP housing or liquid
trapped (gas service) in HP
housing
Vent housing
LP housing gasket leaks
Replace gasket
Range spring broken or
Return BUA for
DPU tampered with
repair
Mechanism
Loose links or movements
Repair or replace
Out of calibration
Calibrate
Erratic
Primary
Flow pulsating
Install dampening
Indication
device upstream of
DPU run
Piping from
Liquid trapped in gas
Remove (see Startup
Primary Element
piping or gas bubble in
Procedure-Section 3)
to DPU
liquid piping
Vapor generator incorrectly Repipe
installed
Reference leg gassy or
See piping instruc-
liquid vaporizing
tions
Bellows Unit
Obstructed bellows travel
Clean bellows
Gas trapped in DPU HP or Remove (see Startup
LP housing
Procedure-Section 3)
Mechanism
Linkage dragging or dirty
Adjust or clean
Pointer dragging on scale
Adjust
plate
26