CAME Z Series Quick Start Manual Download Page 2

2

IT

ALIANO - ENGLISH - ESP

AÑOL

GENERAL SPECIFICATIONS

Description

Electric panel suitable for controlling the 
automation of 230V swing gates with up to 
320W power. 
Fully designed and built by CAME CAN-
CELLI AUTOMATICI S.p.A., it complies 
with regulations in force.
ABS container with IP54 protection level.
The panel runs on 230V with a 50÷60 Hz 
frequency on terminals L-N, and the inlet is 
protected with 5A fuses.
Control circuit and accessory power sup-
ply: 24V, protected by a 1.6A fuse. 
The accessories’ overall wattage must not 
be over 20W.

Safety

Reopening during closure: safety device 
connected with terminals 2-C1. The photo-
electric cells detect an obstacle while the 
gate is closing, causing the gate to reverse 
the direction of movement until it is fully 
open.

Total stop: safety device connected 
to terminals 1-2. The gate stops, 
discontinuing the automatic closure cycle. 
Use the keypad or the radio remote control 
for the gate to resume movement.

Optional accessories

3W max. open gate pilot lamp connected 
to 10-5. Lamp signals the gate’s open 
position.  It turns off when the gate reaches 
the closure end-stop.

Other functions

Automatic closure. The automatic closure 
timer is self-powered in the aperture end-
stop. The adjustable time set in any case 
depends on possible safety accessories 
and is discontinued after a stop or when 
there is no electricity.
Steady movement control. The gate remains 
in function by keeping the key pressed (it 
overrides the radio remote control function). 
It is activated when the T.L. trimmer is set at 
its minimum.

Adjustments

2nd motor closure delay time.
Automatic closure time.
Work time.

Warning! Turn off power supply before 
opening the apparatus.

GB

Summary of Contents for Z Series

Page 1: ...urezza collegato sui morsetti 1 2 Arresto del cancello con l esclusione del ciclo di chiusura automatica per riprendere il movimento del cancello agire sulla pulsantiera o dal radiocomando Accessori o...

Page 2: ...ntil it is fully open Total stop safety device connected to terminals 1 2 The gate stops discontinuing the automatic closure cycle Use the keypad or the radio remote control for the gate to resume mov...

Page 3: ...guridad conectado en los bornes 1 2 Detiene la cancela desconectando el ciclo de cierre autom tico para reanudar el movimiento de la puerta hay que utilizar la botonera o el radiomando Accesorios opci...

Page 4: ...S COMPONENTES MISURE DI INGOMBRO EXTERNAL DIMENSIONS DIMENSIONES M XIMAS LT1 Blu Blue Azul LT2 Bianco White Blanco CT Nero Black Negro 24 Rosa Pink Rosa 12 Viola Purple Violeta 0 Rosso Red Rojo CT Mar...

Page 5: ...delay setting trimmer 3 Automatic closure time setting trimmer 4 5A line fuse 5 1 6A accessory fuse 6 Operating time setting trimmer 7 Function control LED 8 AF radiofrequency slot card 9 Radio code m...

Page 6: ...osure Motor 1 monof sico 230V a c retardado durante el cierre Alimentazione accessori 24V a c max 20W 24V a c Powering accessories max 20W Alimentaci n accesorios 24V a c max 20W Uscita 230V a c in mo...

Page 7: ...chiusura automatica Trimmer T L Regolazione tempo lavoro min 15 max 120 Nota regolando al minimo il tempo lavoro si abilita la funzione di comando ad azione mantenuta Trimmer T R 2 M Adjustment delay...

Page 8: ...rjeta AF Frequenza MHz Frequency MHz Frecuencia MHz Scheda radiofrequenza Radiofrequency board Tarjeta radiofrecuencia Trasmettitore Transmitter Transmisor AM 26 995 AF26 TOP AM 90 900 AF30 TOP FM 26...

Page 9: ...el trasmettitore Transmitter encoding Codificati n transmisores impostare il codice sul dip switch C e il canale su D P1 CH1 e P2 CH2 impostazione di default set the code to dip switch C and channel t...

Page 10: ...placer un cavalier de codifi cation J 3 m moriser le code 4 enlever le cavalier J TOP QUARZATI QUARTZ QUARTZ premere in sequenza P1 o P2 per registrare il codice al decimo impulso un doppio suono con...

Page 11: ...da fig A per eventuali e successive impostazioni su canali diversi vedi fig B The first encoding operation must be carried out whilst keeping the jumpers positioned for channels 1 and 2 as per fig A...

Page 12: ...zione lampeggia vedi fig 1 con un tasto del trasmettitore si invia il codice il led rimarr acceso a segnalare l av venuta memorizzazione fig 2 N B Se in seguito si vuol cambiare codice ba sta ripeter...