ENGLISHENGLISH
ENGLISH
Command devices
Stop button (
(N.C.) contact.
)
Gate stop button with exclusion of automatic closing, to
resume movement press command button or transmitter
button.
If unused, set DIP-switch 9 to ON.
Key switch selector and/or opening button
(
N.O. contact
)
- Command for gate opening.
Safety devices
C1 = (N.C.) contact.
di riapertura durante la chiusura»
Input for safety devices like photocells, sensitive
edges and other devices that comply with EN 12978
regulations. While the gate is closing, opening the
contact will invert movement until it is fully openend.
Shortcircuit 2 and C1 if unused
C1 = (N.C.) contact
di riapertura durante la chiusura»
C3 = N.C.
"partial stop" contact
Input for safety devices like photocells, sensitive edges and
other devices that comply with EN 12978 regulations. Gate
stops if moving, triggering automatic closing .
C3 = N.C. "partial stop" contact
Key switch selector and/or command button
(
N.O. contact
)
- Gate opening and closing commands, pressing the button or
turning the key switch selector, the gate inverts its movement
or stops depending on selection made on the DIP switches (see
selecting functions, DIP switches 1-10)
if unused