Safety devices
Photocells
Confi gure contact CX or CY (NC), safety input for photocells.
See functions for input CX (Function F 2) or CY (Function F 3) in:
- C1 reopening during closing. When the door is closing, opening the contact causes the door to invert its move-
ment until it is completely open;
- C3 partial stop. Stopping of the door, if it is moving, with consequent automatic closing (if the automatic closing
function has been entered);
- C4 obstruction wait. Stopping of the door, if it is moving, which resumes movement once the obstruction is
removed.
By default, the Cx and Cy contacts are deactivated:
Connecting the safety devices (i.e. the safety test)
At each opening and closing command, the control board checks the effi cacy of the safety devices (such as
photocells).
Any malfunction inhibits any command and is signalled as E4 on the display.
Enable function F5 in programming.
p.
23
-
Ma
nu
al
FA01742-EN
- 12/2021 - © CAME S.p.A. -
Th
e c
onte
nts of th
is
m
an
ua
l m
ay b
e c
ha
ng
ed, at a
ny ti
m
e, a
nd w
ith
ou
t n
oti
ce
. - O
rig
in
al
in
str
ucti
on
s
Summary of Contents for VER06DES
Page 1: ...VER06DES VER08DES IT Italiano EN English FR Français RU Pусский FA01742M04 ...
Page 2: ......
Page 33: ...Garage door operator Series VER VER06DES VER08DES INSTALLATION MANUAL EN English FA01742 EN ...
Page 34: ......
Page 66: ......
Page 98: ......