DESCRIPTION
Indoor touch.screen keypad, for managing alarms in areas associated to the keypad,
via preset scenarios confi gured by users having personal User Code.
The keypad comes complete with transponder inserter
, which allows, users having
the SKEYT key, to use all of the keypad's features, except for access to the system's
User Menu. The keypad can be either fl ush or surface mounted to a wall.
Board description
Anti-tamper device
BUS communication LED
Power supply terminals, RS-485 bus, I/O
Display
The back-lit graphic display, is activated by nearing one's hand to the proximity
sensor
. The indications are given on two lines and via an icon that is viewable on
the left side of the display.
The second line of the display show the status of the areas associated to the keypad,
according to the following table:
C h a -
racter
Meaning
in example B, the areas ...
#
Inserted areas
1, 2, 3, 4, 5
U
Areas being inserted (exit time) without any
open outputs
6, 7, 8
P
Areas partially inserted (there is at least one
temporarily excluded input)
9
X
Area being inserted (output time) but not
ready for any open outputs
10
-
Disinserted areas
11, 12, 13
Areas not managed by the keypad.
14, 15, 16
Alphanumeric keypad
Keys
Features
The alphanumeric key are for entering access codes, selecting
areas in during the powering on phase and for changing para-
meters.
Menu browsing and selection keys.
Parameter changing keys.
After entering the code, it allows access to the User Menu. If
pressed form more than fi ve seconds it allows you to access the
Keypad Menu.
Scenarios launching keys.
System powering off keys.
Lighted warnings
LED(color) Status Meaning
(green)
〇
It shows that some inputs are open in the system. If these
correspond to areas of the scenario that you wish to launch,
the keypad will show which ones they are and, to continue, you
will have to close or exclude them temporarily.
It shows that there are no open inputs. The scenario can be
inserted without any problem.
(green)
〇
It shows that the areas are disinserted (system disinserted).
It shows that all of the areas are inserted (system completely
inserted).
It shows that at least one area is inserted (system partially
inserted).
(red)
〇
It shows that the areas are not in state of alarm.
It shows that at least one area is in state of alarm (the system is
state of alarm).
It shows that the system has detected an alarm and that this
has been suppressed. See the events list for a record of alarms.
To remove the warning see the Control Unit's USER MANUAL.