LED(color) Status Meaning
(yellow)
〇
It shows that there are no malfunctions in the system.
It may show that: the 230 V AC power supply network is lacking;
the battery on a peripheral radio needs replacing; there's a fuse
that needs replacing;
a malfunction type input is out of balance; the clock has not been
initialized;
there's a problem on the PSTN or GSM line; the SIM of the GSM
line has expired.
It shows that the battery of the control unit needs replacing.
〇
= Off |
●
= On|
◉
= Flashing
Display icons
Icon
Meaning
CAME logo
System armed
System not armed
System partial armed
Programming
Event memory
User menu
Alarm memory
Alarm memory
Icon
Meaning
Not ready for arming
Generic power supply mal-
function
230 V network power sup-
ply malfunction
Battery malfunction
PSTN line malfunction
GSM line malfunction
Serial connection (local)
Ethernet connection (re-
mote)
Terminal board
+
Power
A
RS485 BUS
B
–
Power supply -
1
I/O
2
The keypad features two terminals, each of which can be confi gured as INPUT
(impulse-counting balancing) or OUTPUT of the control units with fi rmware version
2.1.00 or higher.
If confi gured as OUTPUTs the terminals are of the Open-Collector (O-C.) type. For their
electrical characteristics see the "Technical Data" paragraph.
Technical data
Type
STDCSN - STDCSB
Power supply [V DC]
12 - 15
Maximum current O.C. OUPUT [mA]
20 (for each OUTPUT)
Maximum voltage O.C. OUTPUT [V DC] 15
Maximum draw [mA]
85
Relative humidity (%)
25 - 75, without condensation
Mounting
Fasten the support using the supplied screws, being careful that the anti-removal
device
is resting against the wall and the UP indication is respected. Snap into
place the keypad block into the support. For wall mounting see fi gure
.
For fl ush mounting you will need the optional 001DC00VISIO01 box.
For mounting on cement wall see fi gures
,
whereas for installing on plasterboard
walls please
.
Selections and settings
Keeping the button pressed for about fi ve seconds
, takes you into the Keypad
Menu (which is independent of the control unit menu), from which you can make the
following selections and settings:
Pag.
8
- Manuale
FA
0
11
74
M
4
A
- 0
5/
20
18 - © CAME S.p.A.
- I contenuti del manuale sono da ritenersi suscettibili di modifica in qualsiasi momento senza obbligo di preavviso. - Istruzi
oni originali