Cable types and minimum thicknesses
Connection
Cable type
Cable length
1 < 10 m
Cable length
10 < 20 m
Cable length
20 < 30 m
Control panel power supply 230 V AC
FROR CEI 20-22
CEI EN
50267-2-1
3G x 1.5 mm2
3G x 2.5 mm2
3G x 4 mm2
Command and safety device
2 x 0.5 mm2
Photocell receivers (DIR, DELTA)
4 x 0.5 mm2
Photocell transmitters (DIR, DELTA)
2 x 0.5 mm2
Photocell transmitters and receivers (SIPA 08-09)
SHIELDED (supplied)
max 6 m
Antenna
RG58
max 10 m
Paired or
CAT 5 - U/UTP - AWG 24
max 100 m
Connection to the CRP (Came Remote Protocol)
CAT 5 - U/UTP - AWG 24
max 1000 m
Metal mass detector
(see product literature)
If cable lengths differ from those specified in the table, establish the cable sections depending on the actual power draw of the connected devices and
according to the provisions of regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated according to the actual power draw and distances. If
connecting products that are not contemplated in this manual, see the literature accompanying said products.
⚠
Depending on the distance between ceiling and passage width, the operator may be fastened in two ways:
- if the distance between ceiling and passage width is less than 110 mm, fasten the beam to the wall.
- if the distance between ceiling and passage width is more than 110 mm, fasten the beam to the wall or use the attaching profi le. In the latter
case, fastening the beam is simplifi ed.
INSTALLATION
⚠
The following illustrations are just examples, in that the space available for fastening the operator and accessories varies depending on the
overall dimensions. It is up to the installer/fitter, therefore, to choose the most suitable solution.
⚠
The operator must be mounted by at least two people. Use proper hoisting gear to transport and position the operator.
Check before fastening the beam
(mm)
(mm)
min
min
min
max