ENGLISH

5

4

3

2

 

INSTALLATION

2. Drill two mounting holes (ø 3.4mm or 1/8”).
3. To carry through the wire  to the header, drill a

 

wiring

hole (ø 8mm or 5/16”).

4.  After drilling the holes, remove the Mounting Template.

 

Note

Be sure that the mounting height is within the value of
those in "SPECIFICATION."

1

Remove the cover and attach the sensor with screws.

Plug the Connector for the sensor to that for the cable.

Supply power to the sensor. Adjust the  detection area

and set the various Switches.  (See “ADJUSTMENT.”)

 

Note

Make sure that you connect the cable correctly to the
Control Unit of the door before turning the power on.

1. Put back the cover on the sensor.
2. If wiring is to be exposed, break the Knockout.

Mounting
Template

3m

Max.

Grey         Power Supply
Grey         12 to 30V  AC / DC
White :    COM.
Yellow :    N.O.
Green :    N.C.

 

Note

Connect the cable when main power is turned off.
 

Note

When passing through the cable to the hole, make sure not
to tear shield: otherwise it may cause electric shock or
breakdown of sensor.

6

Knockout

1.  Affix the Mounting Template to the mounting surface.

The cable is arranged to connect to the door
controller properly as shown below.

A       2.00             2.20            2.50             2.70             3.00
B       0.28             0.31            0.35             0.38             0.41
C       0.68             0.75            0.85             0.92             1.02
D       1.18             1.30            1.48             1.59             1.77
E       2.10             2.30            2.60             2.80             3.10
F       0.16             0.18            0.20             0.22             0.25

A    6’  6 3/4”       7’  2 5/8”     8’  2 7/16”    8’ 10 5/16”    9’  10 1/8”
B            11”       1’   3/16”     1’   1  3/4”    1’  2 15/16”   1’  4 9/16”
C    2’  2 3/4”      2’  5 1/2”     2’  9  9/16”     3’     1/4”     3’  4 3/16”
D   3’ 10 7/16”   4’  3  3/16”    4’  10 1/4”     5’  2 5/8”    5’  9 11/16”
E   6’ 10 11/16   7’  6  9/16”     8’  6 3/8”     9’  2 1/4”    10’  2 1/16”
F       6 5/16”        7  1/16”        7   7/8”       8 11/16”       9 13/16”

*The values of the chart blow is of the Emitting Spots, but not of

the Detection Area.
The actual Detection Area may become smaller depending on
the ambiance light and the colour / material of object and the
floor as well as the entry speed of object.

[ m ]

[ feet , inch ]

B

C

D

A

F

E

Detection Areas are shown in the figure below.

After adjustment, turn the power off and on again, be sure to
walk-test all of detection areas.

1st Row
2nd Row
3rd Row
4th Row

: Detection Area

: Emitting Spot

Presence Detection
Motion Detection

Provided Detection Row type

1st

2nd

3rd

4th

DETECTION AREA