P
age
34
- Manual
FA01610-EN
- 08/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
ALTERNATE OPERATION
The first barrier opens, the vehicle passes, the first barrier closes, the second barrier opens, the vehicle passes and the second barrier closes.
Electrical connections
Connect the two electronic boards with a UTP CAT 5 cable.
Fit an RSE card on both control boards, using the RSE_1 connector.
Connect up the electrics for the devices and accessories.
For information on connecting the electrics for the devices and accessories, please see the “ELECTRICAL CONNECTIONS” section.
The control and safety devices must be connected on both electronic boards.
A B GND
A B GND
1
2
3 3P 4
5
7
2 CX CY CZ
FCA CM1 FCC CM2
RSE
A B GND
A B GND
1
2
3 3P 4
5
7
2 CX CY CZ
FCA CM1 FCC CM2
RSE
UTP CAT 5 (max 1000 m)
Programming
Choose one of the two operations described below.
On one of the two barriers, select [Alternate] as type of installation, during the guided procedure.
On one of the two barriers, configure the [RSE_1] function in [Alternate].
It activates the function [Automatic close] on both control boards.
Saving users
For user storage operations, see the [New user] function.
When programming users, do not use the PARTIAL OPENING 2-3P command.
Operating modes
1
ONLY OPEN command (2-3) on barrier A