F31 Closing slow-down
speed
15 = Minimum speed / … / 40 = Maximum speed
Setting the boom closing slow-down speed, calculated as a percentage.
⚠
Warning: the speed parameter fi elds vary according to the type of boom:
- for 2 m booms with a joint, set the slow-down speed percentage from 20 to 40;
- for 4 m booms, set the slow-down speed percentage from 20 to 30.
- for 6 m booms, set the slow-down speed percentage from 15 to 30;
- for 8 m booms, set the slow-down speed percentage from 15 to 20.
F33 Calibration speed
20 = 20% of travel (minimum) / … / 40 = 40% of travel (maximum)
Setting the boom travel automatic-calibration speed, calculated as a percentage.
F34 Travel sensitivity
10 = maximum sensitivity / … / 100 = minimum sensitivity(
default
)
Adjusting obstruction detection sensitivity during travel.
F35 Slow-down sensitivity
10 = maximum sensitivity / … / 100 = minimum sensitivity(
default
)
Adjusting obstruction detection sensitivity during slow-down.
F37 Opening slow-down
point
40 = 40% of travel / … / 60 = 60% of travel
Adjusting the starting point of opening slow-down for the boom as a percentage of the total travel.
Warning! The percentage varies depending on the type of boom:
- for booms with a joint, between 2 m and 4 m, set the percentage from 40 to 60;
- for booms between 6 m and 8 m, set the percentage from 60 to 70.
F38 Closing slow-down point
20 = 20% of travel /… / 75 = 75% of travel
Determining the starting point of closing slow-down, as a percentage of the total travel.
Warning! The percentage varies depending on the type of boom:
- for 2 m booms with a joint, set the speed percentage from 20 to 40;
- for 4 m booms, set the percentage from 40 to 60;
- for 6 m booms, set the percentage from 60 to 70;
- for 8 m booms, set the percentage from 65 to 75.
F49 Managing serial
connection
0 = Deactivated (default) / 1 = Paired / 2 = Alternate / 3 = CRP
To enable paired, alternate or CRP operation.
F50 Save data
0 = Deactivated (
default
) / 1 = Activated
To save users and settings to the memory roll.
This function only appears if a memory roll has been inserted in the electronic board.
F51 Read data
0 = Deactivated (
default
) / 1 = Activated
To load data saved in the memory roll.
This function only appears if a memory roll has been inserted in the electronic board.
F52 Parameters transfer in
paired/alternate mode
0 = Deactivated (
default
) / 1 = Activated
To load parameters from the MASTER barrier to the SLAVE barrier.
This function only appears if function F 49 is set to PAIRED or ALTERNATE operation.
F56 Peripheral number
1 ----> 225
For systems with more than one automation device using a CRP (Came Remote Protocol) connection system, set an address between 1 and
225 for each panel.
F60 Sleep mode
0 = Deactivated (
default
) / 1 = Activated
To reduce the energy consumption in stand-by.
F61 Pre-fl ashing
0 = during opening and closing (default) / 1 = only during closing / 2 = only during opening
After an opening or closing command is given, the fl ashing light connected to 10-E1 fl ashes before the barrier begins to move.
For information on adjusting the time, see function F 21.
F63 Change COM speed
0=1200 Baud / 1=2400 / 2=4800 / 3=9600 / 4=14400 / 5=19200 / 6=38400 / 7=57600 / 8=115200 B
Set the communication speed used in the CRP (Came Remote Protocol) connection system.
U 1 Enter a user
1 = step-by-step command (open-close) / 3 = open command / 4 = partial/pedestrian opening command (for
paired or alternate systems) / 5 = output B1-B2
Enter up to a maximum of 25 users and associate each one with a function chosen from the available options. Use the transmitter or another
command device to do this (see ENTERING A USER WITH AN ASSOCIATED COMMAND).
U 2 Delete a user
Delete a single user (see DELETING A SINGLE USER).
U 3 Delete users
0 = Deactivated / 1 = Delete all users