photocells
DELTA-S
photocells
DELTA
photocells
Safety devices
Configure (N.C.) contacts CX or CY, input for
safety devices such as photocells, that comply with standard EN
12978.
Input CX (function F
2) or CY (function F
3).
C1 reopening while closing. When the boom is closing, opening
the contact causes the motion to invert until fully opened;
C4 obstacle stand-by. It stops the boom, if moving,
and restarts
movement once the obstacle has been removed.
C5 immediate closing. Closing the boom after a vehicle has
passed through the operating area of the safety devices.
C9 immediate closure with obstacle stand-by during closing.
Closing the boom after a vehicle has passed through the
operating area of the safety devices.
During closing, the devices also run function C4, obstacle
stand-by.
If the CX and CY contacts are not used, they must be
disabled during programming.
Open-barrier signal output (contact rating: 24 V AC - 3 W max).
It shows the barrier status (function F 10).
Luminous cord (contact rating: 24 V AC - 32 W max).
It flashes when the boom opens and closes (function F 15).
Signalling devices
Additional light connection output (contact rating: 24 V AC - 25 W max):
- dome flashing light: it flashes when the barrier opens and closes.
- beacon or courtesy light: outdoor light, which can be positioned freely, for better
illumination in the parking/driveway area.
Beacon: it stays on from the moment the boom begins to open until it is fully closed
(including automatic closing time).
Courtesy light: it stays on for a set time of between 60 and 180 seconds (function F 18).