Output to notify the state of the barrier (Contact rated for: 24 V AC - 3 W max.).
it warns of the booms raised position, and switches off when the boom is lowe-
red.
Output for flashing light (Contact rated for: 24 V - 32 W max).
It flashes when the boom is moving.
Alternatively, in functions programming you can activate the flashing for when
the boom is moving and when it is closed. See Dip-switch 3.
ONLY OPEN or OPEN-CLOSED-INVERT (step-step)
function from control device (NO contact, see DIP
switch 2).
Set the jumper as shown in the fi gure.
ONLY CLOSE function from control device (NO
contact).
Warning: in MAINTAINED ACTION mode, the
control device must be connected to 2-4
.
Set the jumper as shown in the fi gure.
OPEN ONLY function from control device with NO contact.
Warning: in MAINTAINED ACTION mode, the control device must be connected to 2-3.
STOP button (NC contact). For stopping the boom while excluding the automatic closing.
To resume movement either press the control button or any other control device.
If unused, set DIP switch 9 to ON.
CONTROL DEVICES
SIGNALING DEVICES
Summary of Contents for G4001
Page 2: ...2 1...
Page 25: ...Automatic barrier GARD series G4000 G4001 G4000N INSTALLATION MANUAL English FA01117 EN...
Page 26: ...2 1...
Page 47: ...p 23 Manual FA01117 EN 03 2018 CAME S p A Translation of the original instructions...
Page 49: ...Barri re automatique s rie GARD G4000 G4001 G4000N MANUEL D INSTALLATION Fran ais FA01117 FR...
Page 50: ...2 1...
Page 71: ...Page 23 Manuel FA01117 FR 03 2018 CAME S p A Traduction des instructions originales...
Page 73: ...GARD G4000 G4001 G4000N FA01117 RU...
Page 74: ...2 1...
Page 79: ...M12 UNI5588 M12x40 UNI 5739 7 FA01117 RU 03 2018 CAME S p A 24 600...
Page 80: ...M12 UNI 5588 8 FA01117 RU 03 2018 CAME S p A CAME www came com...
Page 81: ...UNI 5931 M8x20 9 FA01117 RU 03 2018 CAME S p A...
Page 83: ...45 4 5 200 max 80 max 11 FA01117 RU 03 2018 CAME S p A 45...
Page 86: ...CAME 14 FA01117 RU 03 2018 CAME S p A 24 3 24 32 DIP 3 2 3 DIP 9 2 4 DIP 2...
Page 87: ...RX TX RX TX DIR DELTA S DELTA 15 FA01117 RU 03 2018 CAME S p A C1 C5 C1 2 1 5 DIP 8 ON...
Page 88: ...1 8 9 1 8 9 n o n o 16 FA01117 RU 03 2018 CAME S p A n o 89 n o...
Page 94: ...22 FA01117 RU 03 2018 CAME S p A CAME S p A UNI EN ISO 14001...