SAFETY DEVICES
Photocells
Configure contact CX or CY (NC), safety input for photocells. See CX input functions (Function F2) or CY (Function
F3) in:
- C1 reopening during closing. When the gate is closing, opening the contact triggers the inversion of movement
until the gate is fully open again;
- C2 close back up during opening. When the gate is opening, opening the contact triggers the inversion of
movement until the gate is completely closed.
- C3 partial stop. Opening the contact triggers the gate to stop, if it is moving, and to shift into automatic closing
(if the automatic closing function has been set);
- C4 obstruction wait. Opening the contact triggers the gate to stop, if it is moving, and to resume its movement
once the obstruction is removed.
If contacts CX and CY are not used they should be deactivated during programming.
Photocells (safety test)
Upon each opening and closing command, the board checks the efficiency of the photocells.
Any malfunction will inhibit any command and E 4 will appear on the display.
For this type of connection, enable function F 5.