• Use of the products must be restricted to its intended use 
(i.e. that for which it was expressly built for). Any other use is 
to be considered dangerous. Came Cancelli Automatici S.p.A. 
is not liable for any damage resulting from improper, wrongful 
or unreasonable use •  Keep these warnings with the installa-
tion and use manuals issued with the automated system.

Before installing 

(preliminary check: in case of a negative 

outcome, do not proceed before having 

complied with the safety obligations)

• Make sure that the parts you intend to automate are in 
good working order, and that they are  properly balanced 
and  aligned.  Also,  make  sure  that  proper  mechanical  stops 
are already in place • If the operator will be installed at a 
height  of  less  than  2.5  m  from  the  ground  or  other  access 
level, check whether you will need any protections and/or 
warnings • Any gate leaves, fi tted with pedestrian entrances, 
onto which you will install an operator, must have a blocking 
mechanism when the gate is in motion • Make sure that the 
opening of the automated gate is not an entrapment hazard 
as regards any surrounding fi xed parts • Do not mount the 
operator  upside  down  or  onto  any  elements  that  may  fold 
under its weight. If needed, add suitable reinforcements at 
the points where it is secured • Do not install onto gates on 
either an upward or downward slope (i.e. that are not on fl at, 
level ground) • Check that any lawn watering devices will not 
wet the gearmotor from the bottom up.

Installation

• Carefully section off the entire site to prevent unauthorised  
access, especially by minors and children • Be careful when 
handling operators that weigh more than 20 Kg (see installa-
tion manual). In such cases, employ proper weight handling 
safety equipment • All opening commands (e.g. buttons, key 
selectors, magnetic detectors, etc.) must be installed at least 
1.85 m from the gate’s area of operation perimeter - or where 
they cannot be reached from the outside of the gate. Also, 
the direct commands (e.g. push button, or proximity devices, 
etc.) must be installed at a height of at least 1.5 m and must 
not be accessible to the public • All ‘maintained action’ com-
mands, must be placed where the moving gate leaves, transit 
areas and driveways are completely visible • If missing, ap-
ply a permanent label that shows the position of the release 
mechanism • Before delivering to the client, verify that the 
system is EN 12453 (impact test) standard compliant. Make 
sure that the operator has been properly adjusted and that the 
safety and protection devices, as well as the manual release 

are working properly • Where necessary and in plain sight, 
apply the Warning Sings (e.g. gate plate).

Special instructions and 

advice for users

• Keep the gate’s area of operation clean and clear of any 
obstacles. Trim any vegetation that may interfere with the 
photocells • Do not allow children to play with the fi xed com-
mand  devices,  or  in  the  gate’s  area  of  operation.  Keep  any 
remote control devices (i.e. transmitters) away from the chil-
dren as well • Frequently check the system, to see whether 
any anomalies or signs of wear and tear appear on the moving 
parts, on the component parts, on the securing points, on the 
cables and any accessible connections. Keep any joints (i.e. 
hinges)  lubricated and clean, and do the same where fric-
tion may occur (i.e. slide rails) • Perform functional tests on 
photocells and sensitive edges, every six months. Keep glass 
panels constantly clean (use a slightly water-moistened cloth; 
do not use solvents or any other chemical products) • If the 
system requires repairs or modifi cations, release the operator 
and do not use it until safety conditions have been restored 
• Cut off the power supply before releasing the operator for 
manual openings. See instructions • Users are FORBIDDEN 
to carry out ANY ACTIONS THAT THEY HAVE NOT BEEN 
EXPRESSLY ASKED TO DO OR SO INDICATED in the manu-
als. Any repairs, modifi cations to the settings and extraor-
dinary maintenance MUST BE DONE BY THE TECHNICAL 
ASSISTANCE STAFF • On the periodic maintenance log, note 
down the checks you have done.

Special instructions and 

advice for all

• Avoid working near the hinges or moving mechanical parts 
• Stay clear of the gate’s area of operation when in motion • 
Do not resist the direction of movement of the gate; this may 
present a safety hazard • At all times be extremely careful 
about dangerous points that must be indicated by proper 
pictograms and/or black and yellow stripes • When using 
a selector or command in ‘maintained action’ mode, keep 
checking that there are no people in the area of operation of 
the moving parts. Do this until you release the command • 
The gate may move at any time without warning • Always cut 
the power when cleaning performing maintenance. 

Summary of Contents for FROG A24

Page 1: ...FROG SERIES INSTALLATION MANUAL FROG A24 FROG A24E IN GROUND OPERATOR FOR SWING GATES English EN ...

Page 2: ...ompletely visible If missing ap ply a permanent label that shows the position of the release mechanism Before delivering to the client verify that the system is EN 12453 impact test standard compliant Make sure that the operator has been properly adjusted and that the safety and protection devices as well as the manual release are working properly Where necessary and in plain sight apply the Warni...

Page 3: ...THIS PAGE LEFT INTENTIONALLY BLANK THIS PAGE LEFT INTENTIONALLY BLANK ...

Page 4: ...IED INSTALLERS 2 2 Limits to use This product is engineered and manufactured by CAME CANCELLI AUTOMATICI S p A and complies with current safety regulations The operator is made up of a foundation box a release assembly a gearmotor and a transmission arm Zinc plated press forged fondation box for underground installation On the inside is the release assembly with a customised manual release key and...

Page 5: ... sure you have a suitable omnipolar cut off device with contacts more than 3 mm apart and independent sectioned off power supply Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical damage Fit tubing to drain away any water leaks which may cause oxidation Make sure that any connections inside the case that provide continuance...

Page 6: ... connecting products that are not described in this manual please refer to the instructions that come with said products 5 3 Cable list and minimum thickness Connections Type of cable Length of cable 1 10 m Leng cable 10 20 m Leng cable 20 30 m Control panel power supply 230V FROR CEI 20 22 CEI EN 50267 2 1 3G 1 5 mm2 3G 2 5 mm2 3G 4 mm2 Motor power supply 24V 2 x 1 mm2 2 x 1 5 mm2 2 x 2 5 mm2 Fla...

Page 7: ...ement Fig 3 part 3 making sure it is perfectly levelled and that the upper edge is 3mm above ground level Fig 3 part 4 Plan for the route of the electrical cables according to the command and safety instructions using the apposite hole on the box Fig 3 part 5 Grease the rotation pins of the foundation box and the gate attachment lever the hinge and pin lever must be aligned Position the gate leaf ...

Page 8: ...ontrol panels 6 Connecting to the control panel brown brown blue Power supply Opening deceleration Closing deceleration White Brown Green Green Brown White 5 7 Manual release In emergencies i e power outages the release mechanisms allow the gate to hook back up when closing You may choose among three different release models model A4366 with customised key Fig 5 A model A4365 with tri lobed key an...

Page 9: ...fy users ENGLISH brown blue brown 7 1 Adjusting the brake microswitches Using the motor make so that the gate leaf is max 500mm from being fully opened At this point do a first adjustment of the endstop microswitches positioning them close to the magnet Consider that this type of endstop reads the magnetic field You may have to repeat the procedure to increase the precision of the adjustment fig 6 7 ...

Page 10: ...rroneous or negligent uses Avoid working close to the hinges or other moving mechanical parts Stay out of the opening closing arc when operator is in motion Do not exercise force against the motion of the operator as this could result in potentially dangerous situations Do not allow children to play or loiter within the opening closing arc of the operator Keep remote controls and any other command...

Page 11: ...forming any maintenance procedures cut off the main power to prevent possible accidents due to gate movement To clean the photocells use a water dampened cloth Do not use solvents or other chemical products which may ruin the devices In the event of any strange vibrations or squeaking lubricate the joints with grease as shown in the diagram Make sure there are no plants within the photocell s beam...

Page 12: ...me Date of job Technician s segnature Requester s segnature Job performed _______________________________________________________________________________________ __________________________________________________________________________________________________ Installer s stamp Operator name Date of job Technician s segnature Requester s segnature Job performed ____________________________________...

Page 13: ...e Job performed _______________________________________________________________________________________ __________________________________________________________________________________________________ In its premises CAME cancelli automatici s p a implements an Environmental Management System certified in compliance with the UNI EN ISO 14001 standard to ensure environmental protection Please con...

Page 14: ...tion Solutions Pvt Ltd Automation Solutions Pvt Ltd A 10 Green Park 110016 New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A 11345 NW 122nd St Medley Medley FL 33178 1 305 433 3307 1 305 396 3331 ASIA CAME Asia Pacific CAME Asia Pacific 60 Alexandra Terrace 09 09 Block C The ComTech 118 502 Singapore Singapore 65 6275 8426 65 6275 5...

Reviews: