background image

Pa

g.

 

1111

  - M

an

u

al

 c

od

e: 

11

9

A

U

3

5

11

9

A

U

3

5

 ve

r.

 

1.

0

1.

0

  0

8

/2

0

10  © C

A

M

E c

an

ce

lli

 auto

m

ati

ci

 s.p.a. - T

h

e d

ata a

n

d i

nf

or

m

ati

on r

ep

orte

d i

n th

is

 in

sta

lla

tio

n m

an

u

al

 a

re s

u

sc

ep

tib

le to

 c

h

an

g

e at a

ny ti

m

e a

n

d w

ith

ou

t o

b

lig

ati

on

 o

n C

A

M

E c

an

ce

lli

 auto

m

ati

ci

 s.p.a. to n

otify u

se

rs.

ENGLISH

10 Demolition and disposal

MANUFACTURER’S DECLARATION OF CONFORMITY

Pursuant to annex II B of the Machinery Directive 98/37/EC 

 

CAME Cancelli Automatici S.p.A.

 

via Martiri della Libertà, 15

 

31030 Dosson di Casier - Treviso - ITALY

 

tel (+39) 0422 4940 - fax (+39) 0422 4941

 

internet: www.came.it - e-mail: [email protected] 

Declares under its own responsibility that the equipments for automatic garage doors and gates listed below:

… comply with the National Law related to the following European Directives and to the applicable parts of the 
following Standards.

98/37/CE - 98/79/CE 

M

ACHINERY

 D

IRECTIVE

98/336/CEE - 92/31/CEE 

E

LECTROMAGNETIC

 

COMPATIBILITY

 D

IRECTIVE

73/23/CEE - 93/68/CE 

L

OW

 V

OLTAGE

 D

IRECTIVE

89/106/CEE  

C

ONSTRUCTION

 

PRODUCTS

 D

IRECTIVE

EN 13241-1 

 

EN 12635 

 

EN 61000-6-2   

EN 12453 

 

EN 12978 

 

EN 61000-6-3  

EN 12445 

 

EN 60335-1 

 

EN 60204-1

FROG A24 / FROG A24E

11 Maker’s statement

Reference code to request a true copy of the original: 

DDF B EN A001L

Installer’s stamp

Operator name

Date of job

Technician’s segnature

Requester’s segnature

Job performed _______________________________________________________________________________________
__________________________________________________________________________________________________

Installer’s stamp

Operator name

Date of job

Technician’s segnature

Requester’s segnature

Job performed _______________________________________________________________________________________
__________________________________________________________________________________________________

 In its premises, CAME cancelli automatici s.p.a. implements an Environmental Management System certified in compliance with 

the UNI EN ISO 14001 standard to ensure environmental protection.
Please continue our efforts to protect the environment—which CAME considers one of the cardinal elements in the developmentof its 
operational and market strategies—simply by observing brief recommendations as regards disposal:

 DISPOSAL OF PACKAGING

The packaging components (cardboard, plastic, etc.) are all classifiable as solid urban waste products and may be disposed of easily, 
keeping in mind recycling possibilities.
Prior to disposal, it is always advisable to check specific regulations in force in the place of installation.

PLEASE DISPOSE OF PROPERLY!

 PRODUCT DISPOSAL

Our products are made up of various types of materials. Most of them (aluminium, plastics, iron, electrical wires, etc.) may be disposed 
of in normal garbage collection bins and can be recycled by disposing of in specific recyclable material collection bins and disposal in 
authorized centres. 
Other components (electrical boards, remote control batteries, etc.), however, may contain polluting substances. 
They should therefore be removed and given to qualified service companies for proper disposal.
Prior to disposal, it is always advisable to check specific regulations in force in the place of disposal.

PLEASE DISPOSE OF PROPERLY!

IMPORTANT WARNING!

Do not use the equipment specifi ed here above, before completing the full installation

In full compliance with the Machinery Directive 98/37/EC

MANAGING DIRECTOR

Mr. Gianni Michielan

Summary of Contents for FROG A24

Page 1: ...FROG SERIES INSTALLATION MANUAL FROG A24 FROG A24E IN GROUND OPERATOR FOR SWING GATES English EN ...

Page 2: ...ompletely visible If missing ap ply a permanent label that shows the position of the release mechanism Before delivering to the client verify that the system is EN 12453 impact test standard compliant Make sure that the operator has been properly adjusted and that the safety and protection devices as well as the manual release are working properly Where necessary and in plain sight apply the Warni...

Page 3: ...THIS PAGE LEFT INTENTIONALLY BLANK THIS PAGE LEFT INTENTIONALLY BLANK ...

Page 4: ...IED INSTALLERS 2 2 Limits to use This product is engineered and manufactured by CAME CANCELLI AUTOMATICI S p A and complies with current safety regulations The operator is made up of a foundation box a release assembly a gearmotor and a transmission arm Zinc plated press forged fondation box for underground installation On the inside is the release assembly with a customised manual release key and...

Page 5: ... sure you have a suitable omnipolar cut off device with contacts more than 3 mm apart and independent sectioned off power supply Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical damage Fit tubing to drain away any water leaks which may cause oxidation Make sure that any connections inside the case that provide continuance...

Page 6: ... connecting products that are not described in this manual please refer to the instructions that come with said products 5 3 Cable list and minimum thickness Connections Type of cable Length of cable 1 10 m Leng cable 10 20 m Leng cable 20 30 m Control panel power supply 230V FROR CEI 20 22 CEI EN 50267 2 1 3G 1 5 mm2 3G 2 5 mm2 3G 4 mm2 Motor power supply 24V 2 x 1 mm2 2 x 1 5 mm2 2 x 2 5 mm2 Fla...

Page 7: ...ement Fig 3 part 3 making sure it is perfectly levelled and that the upper edge is 3mm above ground level Fig 3 part 4 Plan for the route of the electrical cables according to the command and safety instructions using the apposite hole on the box Fig 3 part 5 Grease the rotation pins of the foundation box and the gate attachment lever the hinge and pin lever must be aligned Position the gate leaf ...

Page 8: ...ontrol panels 6 Connecting to the control panel brown brown blue Power supply Opening deceleration Closing deceleration White Brown Green Green Brown White 5 7 Manual release In emergencies i e power outages the release mechanisms allow the gate to hook back up when closing You may choose among three different release models model A4366 with customised key Fig 5 A model A4365 with tri lobed key an...

Page 9: ...fy users ENGLISH brown blue brown 7 1 Adjusting the brake microswitches Using the motor make so that the gate leaf is max 500mm from being fully opened At this point do a first adjustment of the endstop microswitches positioning them close to the magnet Consider that this type of endstop reads the magnetic field You may have to repeat the procedure to increase the precision of the adjustment fig 6 7 ...

Page 10: ...rroneous or negligent uses Avoid working close to the hinges or other moving mechanical parts Stay out of the opening closing arc when operator is in motion Do not exercise force against the motion of the operator as this could result in potentially dangerous situations Do not allow children to play or loiter within the opening closing arc of the operator Keep remote controls and any other command...

Page 11: ...forming any maintenance procedures cut off the main power to prevent possible accidents due to gate movement To clean the photocells use a water dampened cloth Do not use solvents or other chemical products which may ruin the devices In the event of any strange vibrations or squeaking lubricate the joints with grease as shown in the diagram Make sure there are no plants within the photocell s beam...

Page 12: ...me Date of job Technician s segnature Requester s segnature Job performed _______________________________________________________________________________________ __________________________________________________________________________________________________ Installer s stamp Operator name Date of job Technician s segnature Requester s segnature Job performed ____________________________________...

Page 13: ...e Job performed _______________________________________________________________________________________ __________________________________________________________________________________________________ In its premises CAME cancelli automatici s p a implements an Environmental Management System certified in compliance with the UNI EN ISO 14001 standard to ensure environmental protection Please con...

Page 14: ...tion Solutions Pvt Ltd Automation Solutions Pvt Ltd A 10 Green Park 110016 New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A 11345 NW 122nd St Medley Medley FL 33178 1 305 433 3307 1 305 396 3331 ASIA CAME Asia Pacific CAME Asia Pacific 60 Alexandra Terrace 09 09 Block C The ComTech 118 502 Singapore Singapore 65 6275 8426 65 6275 5...

Reviews: