Premise

• Employ this product only for the use for which it was expressly made. 
Any other use is dangerous. CAME S.p.A. is not liable for any damage cau-
sed by improper, wrongful and unreasonable use • Keep these warnings 
together with the installation and operation manuals that come with the 
operator. 

Before installing

(checking what's there: if your evaluation is negative, do not proceed be-
fore having complied with all safety requirements) 

• Check that the automated parts are in good mechanical order, that the 
operator is level and aligned, and that it opens and closes properly. Make 
sure you have suitable mechanical stops • If the operator is to be installed 
at a height of over 2.5 m from the ground or other access level, make 
sure you have any necessary protections and/or warnings in place • If 
any pedestrian openings are fi tted into the operator, there must also be a 
a system to block their opening while they are moving • Make sure that 
the opening automated door or gate cannot entrap people against the fi xed 
parts of the operator • Do not install the operator upside down or onto 
elements that could yield and bend. If necessary, add suitable reinforce-
ments to the anchoring points • Do not install door or gate leaves on tilted 
surfaces • Make sure any sprinkler systems cannot wet the operator from 
the ground up • Make sure the temperature range shown on the product 
literature is suitable to the climate where it will be installed • Follow all 
instructions as improper installation may result in serious bodily injury • 
It is important to follow these instructions for the safety of people. Keep 
these instructions. 

Installing

• Suitably section off  and demarcate the entire installation site to pre-
vent unauthorized persons from entering the area, especially minors and 
children • Be careful when handling operators that weigh over 20 kg. If 
need be, use proper safety hoisting equipment • All opening commands 
(that is, buttons, key switches, magnetic readers, and so on)  must be 
installed at least 1.85 m from the perimeter of the gate's working area, 
or where they cannot be reached from outside the gate. Also, any direct 
commands (buttons, touch panels, and so on) must be installed at least 1.5 
m from the ground and must not be reachable by unauthorized persons 
• All maintained action commands, must be fi tted in places from which 
the moving gate leaves and transit and driving areas are visible • Apply, 
if missing, a permanent sign showing the position of the release device • 
Before delivering to the users, make sure the system is EN 12453 standard 
compliant (regarding impact forces), and also make sure the system has 
been properly adjusted and that any safety, protection and manual release 
devices are working properly • Apply Warning Signs (such as the gate's 
plate) where necessary and in a visible place 

Special user-instructions and recommendations 

• Keep gate operation areas clean and free of any obstructions. Make 
sure that the photocells are free of any overgrown vegetation and that 
the operator's area of operation is free of any obstructions • Do not allow 
children to play with fi xed commands, or to loiter in the gate's maneuve-
ring area. Keep any remote control transmitters or any other command 
device away from children, to prevent the operator from being accidentally 
activated. • The apparatus may be used by children of eight years and 
above and by physically, mentally and sensorially challenged people, or 
even ones without any experience, provided this happens under close su-
pervision or once they have been properly instructed to use the apparatus 
safely and about the potential hazards involved. Children must not play 
with the apparatus. Cleaning and maintenance by users must not be done 
by children, unless properly supervised • Frequently check the system 
for any malfunctions or signs of wear and tear or damage to the moving 
structures, to the component parts, all anchoring points, including cables 
and any accessible connections. Keep any hinges, moving joints and slide 
rails properly lubricated • Perform functional checks on the photocells and 
sensitive safety edges, every six months. To check whether the photocells 

are working, wave an object in front of them while the gate is closing; if 
the operator inverts its direction of travel or suddenly stops, the photocells 
are working properly. This is the only maintenance operation to do with 
the power on. Constantly clean the photocells' glass covers using a slightly 
water-moistened cloth; do not use any solvents or other chemical products 
that may ruin the devices • If repairs or modifi cations are required to the 
system, release the operator and do not use it until safety conditions have 
been restored • Cut off  the power supply before releasing the operator for 
manual openings and before any other operation, to prevent potentially 
hazardous situations. Read the instructions • If the power supply cable 
is damaged, it must be replaced by the manufacturer or authorized tech-
nical assistance service, or in any case, by similarly qualifi ed persons, to 
prevent any risk • It is FORBIDDEN for users to perform any OPERATIONS 
THAT ARE NOT EXPRESSLY REQUIRED OF THEM AND WHICH ARE NOT LI-
STED in the manuals. For any repairs, modifi cations and adjustments and 
for extraordinary maintenance, CALL TECHNICAL ASSISTANCE • Log the 
job and checks into the periodic maintenance log. 

Additional special recommendations for everyone 

• Keep away from hinges and mechanical moving parts • Do not enter 
the operator's area of operation when it is moving • Do not counter the 
operator's movement as this could result in dangerous situations • Always 
pay special attention to any dangerous points, which have to be labeled 
with specifi c pictograms and/or black and yellow stripes • While using a 
selector switch or a command in maintained actions, keep checking that 
there are no persons within the operating range of any moving parts, until 
the command is released • The gate may move at any time and without 
warning • Always cut off  the power supply before performing any main-
tenance or cleaning.

Danger of hand crushing 

Danger! High voltage. 

No transiting while maneuvering 

WARNING! 

important safety instructions for people:

READ CAREFULLY! 

Danger of foot crushing 

Summary of Contents for F7000

Page 1: ...F7000 SWING GATE OPERATOR English INSTALLATION MANUAL EN 119DS55EN ...

Page 2: ...as clean and free of any obstructions Make sure that the photocells are free of any overgrown vegetation and that the operator s area of operation is free of any obstructions Do not allow children to play with fixed commands or to loiter in the gate s maneuve ring area Keep any remote control transmitters or any other command device away from children to prevent the operator from being accidentally...

Page 3: ...stallation and use other than that specified in this manual is forbidden 3 Reference standards 2 2 Limitations to use Operator with control board and articulated transmission arm for gate leaves of up to 2 3 m 4 2 Technical data CAME S p A adopts the ISO 9001 certified quality management and the ISO 14001 environmental management systems Came only designs and manufactures in Italy This product is ...

Page 4: ...gation to inform users of said changes 4 4 Dimensions 4 3 Description of parts 1 Operator 2 Post fastening bracket 3 Articulated arm 4 Gate fastening bracket Hinge Closing strike plate i 240 mm max with 90 opening Post Opening angle A B C 90 137 210 0 430 137 205 50 430 137 200 75 430 137 195 100 430 137 190 125 430 137 185 150 400 137 180 175 400 180 175 200 400 110 180 210 0 430 200 205 50 430 ...

Page 5: ... mm2 Motor power supply 230 V 3 x 0 5 mm2 3 x 0 5 mm2 3 x 0 5 mm2 Flashing light 2 x 0 5 mm2 2 x 1 mm2 2 x 1 5 mm2 Photocell transmitters 2 x 0 5 mm2 2 x 0 5 mm2 2 x 0 5 mm2 Photocell receivers 4 x 0 5 mm2 4 x 0 5 mm2 4 x 0 5 mm2 Accessories power source 2 x 0 5 mm2 2 x 0 5 mm2 2 x 1 mm2 Safety and command devices 2 x 0 5 mm2 2 x 0 5 mm2 2 x 0 5 mm2 Antenna RG58 max 10 m 5 Installation Before begi...

Page 6: ...rm users of said changes Make sure you have all the tools and materials needed to carry out the installation in total safety and in accordance with current regulations The figure shows some examples of the tools needed by installers 5 4 Tools and equipment 1 Operator 2 Antenna 3 Flashing light 4 Key switch 5 Photocells 6 Connections junction pit 7 Mechanical stop plates 8 Transmitter 5 3 Standard ...

Page 7: ...using M8 screws and ø 14 plugs while respecting the 100 mm minimum distance from the ground Fasten bracket A to the gate leaf by welding it or using M6 screws and respecting the measurements in the table 2 2 Limitations to use and the 68 mm level difference between the two brackets Post bracket Gate bracket A See chap 4 4 Dimensions Open the lock cover 1 Insert the key push it down and turn it clo...

Page 8: ...ed bracket match the four holes and fasten it using the two issued M8x90 screws and M8 nuts 4 Insert the Ø 10x40 pin and the straight arm into the gearmotor shaft and fasten it using an M10x14 screw and Ø 10x35 washer Lubricate the straight arm pin Join and fasten the two arms with the M6x10 and the Ø 6x24 washer Release the gearmotor and fasten the curved arm to bracket A using the M12x40 screw a...

Page 9: ...rm users of said changes 5 8 Releasing the gearmotor 5 9 Micro switch settings To release the gearmotor used the lever located above the rod RELEASE LOCKING Micro switch Micro switch Upper cam Lower cam Lower cam fastening screw Upper cam fastening screw LIMIT SWITCH ASSEMBLY If the system already has mechanical stops do not lock the cams otherwise calibrate them in the following way ...

Page 10: ...lockwise until the micro switch is activated Use the lateral screws to fasten the cam Micro switch Lower cam fastening screw Lower cam Switch Manually close the gate leaf turn the lower cam clockwise until the micro switch is activated Use the central screw to fasten the cam Upper cam fastening screw Switch Upper cam Micro switch These settings require the gearmotor to be released see releasing th...

Page 11: ...ax 110 Use the central screw to fasten the cam These settings require the gearmotor to be released see releasing the gearmotor Micro switch setting with left side installed gearmotor inside view Micro switch Lower cam fastening screw Lower cam Switch Upper cam fastening screw Switch Upper cam Micro switch Manually close the gate leaf turn the lower cam counter clockwise until the micro switch is a...

Page 12: ... CAME S p A The data and information in this manual may be changed at any time and CAME S p A is under no obligation to inform users of said changes Earthing LEFT gate leaf with delayed CLOSING 5 10 Electrical connections 5 10 1 Electrical connections to the on board control panel with two leaf swing gates RIGHT gate leaf with delayed CLOSING ...

Page 13: ...y time and CAME S p A is under no obligation to inform users of said changes 5 10 2 Electrical connections to the on board control panel with two leaf gates LEFT gate leaf RIGHT gate leaf Once finished with mounting electrical connections and adjustments replace the cover and secure it using the hex nut M4 Insert the release handle into the LOCK position and secure it 5 11 Cover mounting ...

Page 14: ...able command modes are opening closing total stop The photocells after detecting an obstacle may trigger the reopening of the closing gate a total stop Specific trimmers regulate the working time for automatic closing the delayed closing time of gearmotor 2 the working time You can also connect a 12 V electric lock a gate open signal lamp FUSE TABLE to protect fuses for Electronic board line A 5 C...

Page 15: ...changes 6 3 Main components Warning Before acting on the device cut off the mains power supply 1 Connecting terminals 2 Line fuse 3 Accessories fuse 4 Buttons to memorise radio code 5 Trimmer for adjusting the delay of gearmotor 2 6 Working time adjuster trimmer 7 Automatic closing time adjuster trimmer 8 Features selector 9 Radio frequency card socket 10 LED Connect the wires coming out of the bo...

Page 16: ...anged at any time and CAME S p A is under no obligation to inform users of said changes Power supply to the 230V AC 50 60 Hz control panel Terminals for powering the 24V AC accessories Overall allowed power 20W Power supply Connection for the 12 V 15W max electric lock Gearmotor 1 delayed when opening Gearmotor Gearmotor 2 delayed when closing 6 4 Electrical connections ...

Page 17: ...en warning light contact rated for 24 V 3 W Max Warns of open gate position turns off when gate is closed Flashing light contact rated for 230V AC 25W Max Flashes while gate opens and closes Safety devices C1 N C contact for reopening while closing Input for safety devices like photocells sensitive edges and other devices that comply with EN 12978 regulations While the door is closing opening the ...

Page 18: ...d or command button N O contact Commands for opening and closing by pressing the button or turning the selector switch key if unused 1 ON Automatic closing activated 1 OFF deactivated 2 ON Open stop close stop with button 2 7 and radio transmitter 2 OFF Open close with button 2 7 and radio transmitter activated 6 5 Selecting features Command devices 6 6 Settings Trimmer T R 2M Adjusting the delay ...

Page 19: ...he RG58 antenna cable to the corresponding terminals 6 7 Activating the radio command Only for the AF43S AF43SM radio frequency cards position jumper as shown depending on the series of transmitters you are using Plug the radio frequency card into the control board AFTER CUTTING OFF THE MAINS POWER SUPPLY and disconnecting the batteries if any N B The control board only recognises the radio freque...

Page 20: ...A is under no obligation to inform users of said changes 1 Hold down the PROG button on the CONTROL BOARD the LED flashes Memorisation Flashing LED AF radio frequency card N B if you later wish to change code repeat the described sequence LED on AF radio frequency card 2 A transmitter button sends the code and the LED stays lit to show that memorisation has been successful ...

Page 21: ..._____________________________________________________________ __________________________________________________________________________________________________ _______________________________________________________________________________________________ Installer s stamp Product name Date of job Technician s signature Customer s signature Job carried out ________________________________________...

Page 22: ...________________________________________________________________________ Installer s stamp Product name Date of job Technician s signature Customer s signature Job carried out _______________________________________________________________________________________ __________________________________________________________________________________________________ _____________________________________...

Page 23: ... simply by separating them for recycling Before proceeding it is always a good idea to check your local legislation on the matter DISPOSE OF CAREFULLY PRODUCT DISPOSAL Our products are made up of various materials Most of these aluminium plastic iron electric cables are household waste These can be disposed of at local household waste management dumps or recycling plants Other components i e contr...

Page 24: ...mocy technicznej w Waszym języku znajdują się na stronie RU Для получения дополнительной информации о компании продукции и сервисной поддержке на вашем языке HU A vállalatra termékeire és a műszaki szervizre vonatkozó minden további információért az Ön nyelvén HR Za sve dodatne informacije o poduzeću proizvodima i tehničkoj podršci UK Для отримання будь якої іншої інформації про компанію продукцію...

Reviews: