F1
Total stop [1-2]
0 = Disabled (default) / 1 = Enabled
NC input - The door is stopped and any automatic closing is disabled. To resume movement, use the control device. The
safety device must be inserted on [1-2].
F2
Input [2-CX]
0 = Disabled (default) / 1 = C1 / 4 = C4 / 7 = C7
NC input - Possibility of associating: C1 = reopening during closing for photocells, C4 = obstacle wait, C7 = reopening
during closing for sensitive edges.
F3
Input [2-CY]
0 = Disabled (default) / 1 = C1 / 4 = C4 / 7 = C7
NC input - Possibility of associating: C1 = reopening during closing for photocells, C4 = obstacle wait, C7 = reopening
during closing for sensitive edges.
F5
Safety test
0 = Disabled (default) / 1 = CX / 2 = CY / 3 = CX+CY
After each opening or closing command, the panel checks that the photocells work.
F6
Hold-to-run
0 = Disabled (default) / 1 = Enabled
The door opens and closes when a button is pressed. Button to open the contact [2-3] and button to close the contact [2-4].
All other control devices, also radio, are disabled.
F7
Command [2-7]
0 = step-by-step (default) / 1 = sequential
Step-by-step = open-close, sequential = open-stop-close-stop.
F8
Command [2-3]
0 = opening (default) / 1 = partial opening
Opening (opening of the door) or partial opening (partial opening of the door: the degree of opening depends on the percenta-
ge of the stroke adjustment set with F36).
F9
Obstacle detection with the motor at a standstill
0 = Disabled (default) / 1 = Enabled
With the door closed, open or after a total stop, the motor remains at a standstill if the safety devices (photocells or sensitive
edges) detect an obstacle.
F11 Encoder disabling
0 = encoder enabled (default) / 1 = encoder disabled
Excludes management of slowdowns, obstacle detection and sensitivity.
F13
Closing thrust
0 = Disabled (default) / 1 = minimum thrust / 2 = medium thrust / 3 = maximum thrust
At the end of the closing run, the gearmotor performs a short thrust to the end.
F18 LED
lamp
0 = Lamp / 1 = Cycle / 2 = Courtesy (default)
In lamp mode, it only remains on during door opening and closing movements.
In cycle mode, it remains on from the start of opening to complete closing, including the wait time before automatic closing.
In courtesy mode, it remains on from when the command is sent to the operator for a settable time, see F25.
F19
Automatic closing time
0 = Disabled (default) / 1 = 1 s / 2 = 2 s / … / 180 = 180 s
The wait before automatic closing starts from reaching the end run point for a time that can be set between 1 and 180
seconds. Automatic closing is not activated in the event the safety devices intervene after detecting an obstacle, after a total
stop or in the event of a power failure.
F21 Pre-fl ashing time
0 = Disabled (default) / 1 = 1 s / 2 = 2 s / … / 5 = 5 s
When an opening or closing command is sent, the fl ashing light on [10-E] fl ashes before starting the manoeuvre. The
fl ashing time can be adjusted from 1 s to 5 s.
F22 Working
time
5 = 5 s / 6 = 6 s / … / 120 = 120 s (default)
Motor operating time, during opening and closing. This can be set between 5 and 120 seconds.
F25
Courtesy lamp time
60 = 60 s (default) / 61 = 61 s / … / 250 = 250 s
LED lamp, remains on for a time necessary during door opening/closing manoeuvres.
This can be set between 60 and 250 seconds.
Function menu
Summary of Contents for EMEGA
Page 33: ...EM4024CB INSTALLATION MANUAL EN English FA01195 EN Operator for overhead doors...
Page 65: ...EM4024CB MANUEL D INSTALLATION FR Fran ais FA01195 FR Automatisme pour portes basculantes...
Page 97: ...EM4024CB RU P FA01195 RU...
Page 98: ...2 2 FA01195 RU 06 2018 CAME S p A CAME S p A 2 5 20 1 85 1 5 EN 12453 20...
Page 103: ...110 A 15 mm min min 15 mm 110 7 7 FA01195 RU 06 2018 CAME S p A 15 110...
Page 105: ...L2 10 mm L1 10 mm 35 35 L1 L2 9 9 FA01195 RU 06 2018 CAME S p A 35 MM MM...
Page 106: ...5 5 10 10 FA01195 RU 06 2018 CAME S p A 5...
Page 107: ...15 mm min min 15 mm 11 11 FA01195 RU 06 2018 CAME S p A...
Page 121: ...I 3 a I L C I p o 25 25 FA01195 RU 06 2018 CAME S p A 3 ENTER 1 ENTER 1 3 2 3...