Page
23
- Manual
FA01947-EN
- 03/2023 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
21
Deleting all users
Select the DIP switches as shown, and press and hold P1 for 5 seconds.
Once all users have been deleted, the LED will remain on and the buzzer will sound for 1 second.
The LED will flash and the buzzer will sound twice.
22
Resetting parameters
Select the DIP switches as shown and press P1.
The LED will flash and the buzzer will sound twice.
N.B. This function cancels all stored transmitters (users).
Adjusting the trimmers
+
_
A.C.T.
+
_
SP. SLOW
+
_
SENS.
1
A.C.T. trimmer
2
SP. SLOW trimmer
3
SENS. trimmer
A.C.T. trimmer
Use this trimmer to adjust the automatic closing wait time: from 1 to 120 seconds.
SP. SLOW trimmer
Use the trimmer to adjust the operator slowdown speed from 30% (-) to 60% (+) of the maximum manoeuvre speed.
SENS. trimmer
Use this trimmer to adjust the obstacle detection sensitivity during operator manoeuvres, from minimum sensitivity (-) to maximum sensitivity (+).
Alert LED
1
CX LED (yellow)
This LED signals that the contact 2-CX (NC) is open. The photocells have detected an obstacle.
2
LED 1 (yellow)
This LED signals that the contact 1-2 (NC) is open. A STOP command has been sent using a button.
3
LED 3P (yellow)
This LED signals that the contact 2-3P (NO) is closed. A partial opening command has been sent.
4
LED 7 (yellow)
This LED signals that the contact 2-7 (NO) is closed. A command has been sent.
5
PRG LED (red)
This LED signals the function programming phases, the automatic closing wait time and any errors or faults.
6
PWR LED (red)
This LED signals that there is a mains power supply to the board.