Page
22
- Manual
FA01947-EN
- 03/2023 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
12
Encoder
The function is enabled by default. To disable it, select the DIP switches as shown and press P1.
The LED will flash and the buzzer will sound twice.
To return to the default setting, press P1 again.
The LED will remain on and the buzzer will sound for 1 second.
13
Hold-to-run
The function is disabled by default. To enable it, select the DIP switches as shown and press P1.
The LED will remain on and the buzzer will sound for 1 second.
To return to the default setting, press P1 again.
The LED will flash and the buzzer will sound twice.
To open and close the gate, press and hold the opening button (button connected on 2-3P – NO contact) or the closing button (button connected on 2-7 – NO
contact).
The hold-to-run command excludes all other control devices, including radio devices.
14
Pre-flashing
The function is disabled by default. To enable it, select the DIP switches as shown and press P1.
The LED will remain on and the buzzer will sound for 1 second.
To return to the default setting, press P1 again.
The LED will flash and the buzzer will sound twice.
15
Adjusting the manoeuvre speed
The default manoeuvring speed is set to 100%. To reduce the speed to 60%, select the DIP switches as shown and press P1.
The LED will remain on and the buzzer will sound for 1 second.
To return to the default setting, press P1 again.
The LED will flash and the buzzer will sound twice.
16
Storing the trimmer value
Use this function to adjust the automatic closing wait time (A.C.T.), slowdown speed (SP.RAL.) and sensitivity (SENS.) using the trimmers.
To store the values, select the DIP switches as shown and press P1.
The LED will remain on and the buzzer will sound for 1 second.
Store the adjustments made using the trimmers so as not to lose the data.
17
Transmitter-activated partial opening
Up to 25 transmitters (users) can be stored.
Select the DIP switches as shown and press P1. The LED will flash.
Press the button on the transmitter you want to store as partial within 10 seconds.
The LED will light up and the buzzer will sound for 1 second.
If the transmitter has already been stored, the LED will flash quickly and the buzzer will sound 4 times.
18
Transmitter-activated open only
Up to 25 transmitters (users) can be stored.
Select the DIP switches as shown and press P1. The LED will flash.
Press the button on the transmitter you want to store within 10 seconds.
The LED will light up and the buzzer will sound for 1 second.
If the transmitter has already been stored, the LED will flash quickly and the buzzer will sound 4 times.
19
Transmitter-activated OPEN-CLOSE-INVERT
Up to 25 transmitters (users) can be stored.
Select the DIP switches as shown and press P1. The LED will flash.
Press the button on the transmitter you want to store within 10 seconds.
The LED will light up and the buzzer will sound for 1 second.
If the transmitter has already been stored, the LED will flash quickly and the buzzer will sound 4 times.
20
Transmitter-activated OPEN-STOP-CLOSE-STOP
Up to 25 transmitters (users) can be stored.
Select the DIP switches as shown and press P1. The LED will flash.
Press the button on the transmitter you want to store within 10 seconds.
The LED will light up and the buzzer will sound for 1 second.
If the transmitter has already been stored, the LED will flash quickly and the buzzer will sound 4 times.