PAIRED OPERATION OR CRP (CAME REMOTE PROTOCOL)
RIO WIRELESS DEVICES
Plug the RIOCN8WS card into its corresponding connector on the control board.
Set the function to be associated to the wireless device (F65, F66, F67 e F68).
Confi gure the RIOED8WS, RIOPH8WS andRIOLX8WS wireless accessories by following the indications shown in the folder enclosed with each
accessory.
If the devices are not confi gured with the RIOCN8WS card, the display will read out E18.
⚠
If there are any radio-frequency disturbances to the system, the wireless system will inhibit the normal operation of the operator, and this error
will show up on the display as E17.
Fit the RSE card.
WARNING! For the system to work properly, before
fitting the control board, you MUST CUT OFF
THE POWER MAINS and remove any emergency
batteries.
Serial RS485 connection via CRP (Came Remote Protocol) or
for paired operation (see chapter called PAIRED OPERATION).
Sensitive Safety Edges
Configure contact CX or CY (NC), safety input for sensitive safety-edges.
See functionsF2 (input CX)or F3 (input CY) in:
- C7 (sensitive safety edges with clean contact) or r7 (sensitive safety edges with 8K2 resistance), reopening during closing. When the gate is closing,
opening the contact triggers the inversion of movement until the gate is fully open again;
- C8 (sensitive safety edges with clean contact) or r8 (sensitive safety edge with 8K2 resistance), reclosing during opening. When the gate is opening,
opening the contact triggers the inversion of movement until the gate is completely closed.
If unused, contacts CX and CY should be deactivated during programming.
DFWN with DFI card for controlling the
connnections
DFWN