WARNING!

Important instructions for the safety of people: 

READ CAREFULLY!

Foreword

• Use of the products must be restricted to its intended use 
(i.e. that for which it was expressly built for). Any other use is 
to be considered dangerous. Came Cancelli Automatici S.p.A. 
is not liable for any damage resulting from improper, wrongful 
or unreasonable use •  Keep these warnings with the installa-
tion and use manuals issued with the automated system.

Before installing 

(preliminary check: in case of a negative 

outcome, do not proceed before having 

complied with the safety obligations)

• Make sure that the parts you intend to automate are in 
good working order, and that they are  properly balanced 
and  aligned.  Also,  make  sure  that  proper  mechanical  stops 
are already in place • If the operator will be installed at a 
height  of  less  than  2.5  m  from  the  ground  or  other  access 
level, check whether you will need any protections and/or 
warnings • Any gate leaves, fi tted with pedestrian entrances, 
onto which you will install an operator, must have a blocking 
mechanism when the gate is in motion • Make sure that the 
opening of the automated gate is not an entrapment hazard 
as regards any surrounding fi xed parts • Do not mount the 
operator  upside  down  or  onto  any  elements  that  may  fold 
under its weight. If needed, add suitable reinforcements at 
the points where it is secured • Do not install onto gates on 
either an upward or downward slope (i.e. that are not on fl at, 
level ground) • Check that any lawn watering devices will not 
wet the gearmotor from the bottom up.

Installation

• Carefully section off the entire site to prevent unauthorised  
access, especially by minors and children • Be careful when 
handling operators that weigh more than 20 Kg (see installa-
tion manual). In such cases, employ proper weight handling 
safety equipment • All opening commands (e.g. buttons, key 
selectors, magnetic detectors, etc.) must be installed at least 
1.85 m from the gate’s area of operation perimeter - or where 
they cannot be reached from the outside of the gate. Also, 
the direct commands (e.g. push button, or proximity devices, 
etc.) must be installed at a height of at least 1.5 m and must 
not be accessible to the public • All ‘maintained action’ com-
mands, must be placed where the moving gate leaves, transit 
areas and driveways are completely visible • If missing, ap-
ply a permanent label that shows the position of the release 
mechanism • Before delivering to the client, verify that the 
system is EN 12453 (impact test) standard compliant. Make 
sure that the operator has been properly adjusted and that the 
safety and protection devices, as well as the manual release 

are working properly • Where necessary and in plain sight, 
apply the Warning Sings (e.g. gate plate).

Special instructions and 

advice for users

• Keep the gate’s area of operation clean and clear of any 
obstacles. Trim any vegetation that may interfere with the 
photocells • Do not allow children to play with the fi xed com-
mand  devices,  or  in  the  gate’s  area  of  operation.  Keep  any 
remote control devices (i.e. transmitters) away from the chil-
dren as well • Frequently check the system, to see whether 
any anomalies or signs of wear and tear appear on the moving 
parts, on the component parts, on the securing points, on the 
cables and any accessible connections. Keep any joints (i.e. 
hinges)  lubricated and clean, and do the same where fric-
tion may occur (i.e. slide rails) • Perform functional tests on 
photocells and sensitive edges, every six months. Keep glass 
panels constantly clean (use a slightly water-moistened cloth; 
do not use solvents or any other chemical products) • If the 
system requires repairs or modifi cations, release the operator 
and do not use it until safety conditions have been restored 
• Cut off the power supply before releasing the operator for 
manual openings. See instructions • Users are FORBIDDEN 
to carry out ANY ACTIONS THAT THEY HAVE NOT BEEN 
EXPRESSLY ASKED TO DO OR SO INDICATED in the manu-
als. Any repairs, modifi cations to the settings and extraor-
dinary maintenance MUST BE DONE BY THE TECHNICAL 
ASSISTANCE STAFF • On the periodic maintenance log, note 
down the checks you have done.

Special instructions and 

advice for all

• Avoid working near the hinges or moving mechanical parts 
• Stay clear of the gate’s area of operation when in motion • 
Do not resist the direction of movement of the gate; this may 
present a safety hazard • At all times be extremely careful 
about dangerous points that must be indicated by proper 
pictograms and/or black and yellow stripes • When using 
a selector or command in ‘maintained action’ mode, keep 
checking that there are no people in the area of operation of 
the moving parts. Do this until you release the command • 
The gate may move at any time without warning • Always cut 
the power when cleaning performing maintenance. 

www.metalines.com

[email protected]

Summary of Contents for BK 800

Page 1: ...INSTALLATION MANUAL BK 800 1200 1800 2200 BKE 1200 1800 2200 AUTOMATION FOR SLIDING GATES English EN 119BS04EN www metalines com sales metalines com...

Page 2: ...missing ap ply a permanent label that shows the position of the release mechanism Before delivering to the client verify that the system is EN 12453 impact test standard compliant Make sure that the o...

Page 3: ...www metalines com sales metalines com...

Page 4: ...mple 1 2 chain 009 CGIU 1 2 chain joint Important Check that the safety equipment and accessories are CAME originals this is a guarantee that also makes the system easy to set up and upkeep Descriptio...

Page 5: ...tor 2 Board cover support 3 End stop flaps 4 ZBK ZBKE basic control board 5 Electric board front cover 6 Release door 7 Base plate 8 Securing screws 9 Plates for securing screws 10 Nuts ACCESSORIES 1...

Page 6: ...al conductive parts Set up suitable tubing and trenching to allow for electrical cables to pass making sure they are free from any potential mechanical damage Only expert qualified personnel must carr...

Page 7: ...embedded in the concrete in the positions indicated the drive unit is then attached to this bots The anchor plate must be perfectly level and absolutly clean the bolts threads must be completly expos...

Page 8: ...ow Release the gearmotor position the rack on the pinion of the gearmotor and slide the gate manually in order to attach the rack along its entire length when the rack is attached to the gate adjust t...

Page 9: ...whose positions determine the limits of gate travel on the rack Note do not allow the gate to strike the mechanical stops in the open or closed positions Manual release of the gearmotor To open the ac...

Page 10: ...y closes it Warning After the gate s direction is inverted three consecutive times the gate remains opened excluding the automatic closing function use the remote control or push button to close the g...

Page 11: ...nection Connection for the limit switch unit BK series ORANGE RED WHITE Connection for gear motor limit switch or encoder RED Invert the phases of the gear motor U V On the BK series invert wires FA F...

Page 12: ...t gate leaf is open and turns off when the gate is closed Courtesy lamp Contact output 230V 60 V max Auxiliary connection for suitably positioned external lamp to increase lighting of the steering are...

Page 13: ...the direction of movement until the gate leaf is fully open N C contact for partial stop Input for safety devi ces such as photocells sensitive safety edges and other devices compliant with EN 12978...

Page 14: ...sed by acting on their corresponding DIPs see selecting functions Electrical connection for the check of the operating state of the photocells A C T Trimmer Automatic Closing Time This adjusts the gat...

Page 15: ...losing they trigger an inversion of direction movement until full opening is achieved insert the safety device into terminal 2 C1 if not used set dip switch to ON 8 OFF 9 OFF Re closing during opening...

Page 16: ...ate leaf press the CLOSE button the led indicator keeps ashing as long as button is kept pressed 3 Manually open the gate leaf press the OPEN button the led code indi cator keeps ashing as long as the...

Page 17: ...es while on the control board of the 2nd motor position dip switch 11 to the ON position to place it into a slave state N B Make sure that the radio frequency board is inserted only into the Master bo...

Page 18: ...ying the transmitter memorizing the code on the command board Radio board AF Motherboard 2 The AF board must ALWAYS be inserted into the coupling ref point 5 page 8 when the power is off because the m...

Page 19: ...158 ATOMO AT01 AT02 AT04 CAME CAME CAME CAME CAME CAME CAME CAME CAME CAME Pag 17 17 Manual code 119BS04EN 119BS04EN ver 6 6 04 2013 CAME cancelli automatici s p a The data and information reported in...

Page 20: ...sequence described above CH2 Channel for direct commands to an auxiliary device or for the control of two paired motors con nected to B1 B2 Memorizing the code on the command board CH1 Channel for di...

Page 21: ...Prior to disposal it is always advisable to check speci c regulations in force in the place of installation PLEASE DISPOSE OF PROPERLY PRODUCT DISPOSAL Our products are made up of various types of ma...

Page 22: ...empresa los productos y asistencia en su idioma NL Voor meer informatie over het bedrijf de producten en hulp in uw eigen taal PT Para toda e qualquer informa o acerca da empresa de produtos e assist...

Reviews: