GENERAL INSTRUCTIONS FOR INSTALLING
⚠
Installation must be carried out by expert qualified personnel and in full compliance with the regulations in force.
Important! Using original CAME control and safety devices and accessories ensures easy installation and system maintenance.
Preliminary checks
⚠
Before beginning, do the following::
• make sure the plate is anchored to a solid spot;
• make sure you have set up a suitable dual pole cut off device along the power supply that is compliant with the installation rules. It should
completely cut off the power supply according to category III surcharge conditions (that is, with minimum contact openings of 3 mm);
• make sure that any connections inside the case (that provide continuance to the protective circuit) are fitted with extra insulation as compared
to the other conductive parts inside;
• set up suitable tubes and conduits for the electric cables to pass through, making sure they are protected from any mechanical damage.
Tools and materials
Make sure you have all the tools and materials you need for installation at hand to work in complete safety and compliance with the current
regulations. The following figure shows some basic equipment needed by the installer.
Connection
Cable type
Cable length
1 < 15 m
Cable length
15 < 30 m
Power supply 230 V AC
H05RN-F
3G x 1.5 mm2
3G x 2.5 mm2
Flashing light
FROR CEI
20-22
CEI EN
50267-2-1
2 x 0,5 mm2
-
Photocell transmitters
2 x 0,5 mm2
Photocell receivers
4 x 0,5 mm2
Command and safety device
2 x 0,5 mm2
Antenna
RG58
max 10 m
Metal mass detector
(see product literature)
If cable lengths differ from those specified in the table, establish the cable sections depending on the actual power draw of the connected
devices and according to the provisions of regulation CEI EN 60204-1.
For connections that require several, sequential loads, the sizes given in the table must be re-evaluated based on actual power draw and distances.
When connecting products that are not specified in this manual, please refer to the documentation provided with said products.
Types of cable and minimum sizes